RE: Grant 13kW Aerona3 - issues getting zones to temp

@crimson The next stage might be to fit the larger radiators downstairs; this will have several benifits, not only will it heat downstairs more effici...

1 year ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

Thank you Derek, at least it is only a little ‘Devil’ then! Regards, Toodles.

1 year ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

I suspect that the image was subjected to some filesize reduction so here is a close up of the displays. Toodles.

1 year ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

@iancalderbank In my own case, I started from the coolest room with that Lockshield valve fully open, then progressed around the house from the warmes...

1 year ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

@derek-m Hello Derek, I have left the system running with the thermometers in place for a few weeks now; glancing at the readings from time to time in...

1 year ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

@crimson I’m not Ian, but, not really! The lockshield is a restriction to flow which is set and remains constant. A TRV provides dynamic changes with ...

1 year ago
Reply
RE: Dual Fuel Towel Rail valve settings.

@judith I have an update of a sort to report: We use the electrical element during the winter too! I find that (particularly in mild weather) the radi...

1 year ago
Reply
RE: Maximising Savings: Navigating My First Year with Octopus Energy and Heat Pump Running Costs

@allyfish I was watching a very recent Youtube presentation from Anthony Dyer in Aberdeen who has presented quite a few on subjects including his PV, ...

1 year ago
Reply
RE: Maximising Savings: Navigating My First Year with Octopus Energy and Heat Pump Running Costs

@allyfish Indeed Allyfish, swapping from one tariff to the other only takes a couple of days and, as you say, one can swap back again if wished; there...

1 year ago
Reply
RE: Maximising Savings: Navigating My First Year with Octopus Energy and Heat Pump Running Costs

Oh Steve D! I think you are very nearly my double! I too have been along a very similar journey; we have 8.1 kWp of PV and are fortunate to have 27 kW...

1 year ago