RE: ASHP and how it should run and potential kw consumption?

@jamespa I have a setback of 2C at the moment with a cheap overnight tariff. To overcome the slow recovery issue I am currently experimenting with t...

9 months ago
Reply
RE: New 5kW Samsung Gen6 heat pump owner with loads of questions

@bontwoody Thanks for that snippet of information! You have just saved me from doing an alteration to my system that would have been a complete w...

9 months ago
Reply
RE: How to increase DHW water temperature on Samsung Gen 6 Control Panel

@misiak I think this is a link to the heatgeek resource

9 months ago
Reply
RE: How to increase DHW water temperature on Samsung Gen 6 Control Panel

@misiak Hello. The Samsung pump is capable of generating a flow temperature of up to 70C. The heat transfer into DHW (depends on storage tank efficien...

9 months ago
Reply
RE: New 5kW Samsung Gen6 heat pump owner with loads of questions

@jamespa @johnr from my understanding COP is the ratio of how much heat energy a thermal machine can move compared to the work (electrical input) done...

10 months ago
Reply
RE: New 5kW Samsung Gen6 heat pump owner with loads of questions

@johnnyb to be fair I did not know in the beginning either. I had to do my own research and experimentation to understand what was going on. This li...

10 months ago
Reply
RE: New 5kW Samsung Gen6 heat pump owner with loads of questions

@johnnyb If it is any help, I calculate the COP / SCOP using the following formula for my Samsung heat pump ( Energy Generated + Energy In ) / E...

10 months ago
Reply
RE: In the Bleak Midwinter... Midea heat pump performance, poor COP and windchill in action

@cathoderay this looks similiar to a phenomenon I experienced while setting up my weather curve. I fixed my issue by slightly increasing the flow te...

11 months ago
Reply
RE: ASHP noise, and running a high temperature heat pump at low temperature

@ccap running my oil boiler is just a personal choice for me. My heat pump is physically capable of heating the house to about -6C OAT before it will ...

12 months ago
Reply
RE: ASHP noise, and running a high temperature heat pump at low temperature

@ccap just to give you some rough comparisons, I have a Samsung 12Kw HT Quiet unit which most of the time produces a flow temperature in the 30C range...

12 months ago
Reply
RE: Heat pumps don't work: debunking myths & misconceptions

@editor If I was in your shoes I would be making fitting a smart meter a priority. I know they have had bad press recently but smart meters open up a ...

1 year ago
Reply
RE: Heat pumps don't work: debunking myths & misconceptions

@editor I guess the DWH strategy used can be influenced by the tariff one is on. For example I have a 200 litre DHW tank with an Octopus Go tariff. ...