Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 31, 2026
@william1066 I think that you're right - dropping the LWT always improves the COP of the compressor. The DeltaT is pretty much irrelevent to the c...
Groundsource is usually a lot simpler - a lot of them are just simple on/off things just like an old fridge, controlled by relays and thermostats. Th...
@murchison2003 Our heatpump is tiny. It takes 1800W from the ground outside, using 600W of electricity. So that 1800W from outside over 200m (30m...
@derek-m It is gshp yes! 230m of pipe buried in the back garden, 800mm down. Had it for just over a year, all good so far:-)
@derek-m Cheers, I’ve obsessively been insulating for years, I need a new hobby! @kev-m It’s actually LWT-Tgroundwater. Not that it makes a h...
Our heatpump has been going for 13 months, used 1580kWh of electricity, and produced 5803kWh of heat. Most of that is heating the (4 bed 1963 build) ...
I started by cable tying temp sensors to pipes, and wrapping with loads of insulation, re-wrapping, getting a different answer... There is no doubt i...
In my experience, the temperature is much harder to monitor accurately enough than the flow rate. We need two sensors well connected to the flow and ...
@iancalderbank The flowmeters I use are cheapie £8 things that look like this from Amazon, which claims 2%. I have two, one on the house circuit m...
@derek-m The sensors are tsic506f, and they connect up to an mbed(old micro type I’m used to) that I programmed with a free Arm account. There’s a...
I used a couple of 0.1C accurate temperature sensors for flow and return - they’re pushed into thin copper tubes which are thoroughly soldered to the ...
We changed the glass in our circa 1990 uPVC windows 11 years ago. The double glazing units that were in were the standard of the time: 4mm glass/16mm...
- 27 Forums
- 2,741 Topics
- 64.3 K Posts
- 527 Online
- 7,144 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Electricity price predictions
Agreed - there's a place for everything from "Dunno, I ...
By EtchedPixels , 31 minutes ago
-
Further, there was a long discussion of the benefits of...
By Old_Scientist , 3 hours ago
-
I appreciate that EnergyPlus is Valliant's first attemp...
By L8Again , 3 hours ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Unfortunately the answer is Yes you will need a new FTC...
By F1p , 18 hours ago
-
RE: PV and battery long payback - sense check query
So if it helps I was recently quoted about 8 grand for ...
By EtchedPixels , 18 hours ago
-
RE: HomeTherma Is Live: A New Home-Energy Platform Built Around the Homeowner
Signed up!
By bobflux , 1 day ago
-
RE: Indevolt Batteries UK Support & Info Thread
I had a quick look and they are a little vague. They ...
By BlizzardGreen , 2 days ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Oh dear. Glad it was replaced. I have been mighty imp...
By JamesPa , 2 days ago
-
RE: Can I start an argument about buffer tanks please? 🙂
Dont, just adjust the LSVs to get different temperature...
By JamesPa , 3 days ago
-
RE: Heat pump running costs – what has actually worked for you?
I installed the air source heat pump in January 2026, i...
By bobflux , 3 days ago
-
RE: Grant Aerona Air to Water R290 6.5 kW - Quiet Mark and Silent Running
Thats all interesting. DHW on my Vailant seems to respe...
By JamesPa , 3 days ago