@jamespa Small mid-terrace so everything is is in closr proximity. Only thing I could do is try to swap the cheap plastic pipe clips for rubber isolat...
My 4KW Daikin will heat my 180L tank in 30 mins to 48C. Most likely less demand but in the ball park. The COP is not as mine reports 2 at worst. I o...
After installation the system did develop a noise in the volumizer and that turned out to be a bleed valve. Which when fixed caused a squeal in the ba...
So after a week of playing with the LWT mode I'm now back to setting my WDC LWT minimum flow temp to 25C. Below this the HP does not resume reliably t...
This is how Adam from Heat Geeks advocates as the best way to set up a heat pump. Then, once you've established a decent WDC matched to your property'...
@jancold Not a plumber but I believe that is the blending valve and pressure regulator. No experience on how to adjust it. Another thoug...
Have you considered the Thermostatic Mixing (Blending) Valve (aka Anti-Scald or Tempering Valve) that mixes the hot water with mains to control the te...
This is how Daikin run their heat pumps. Weather Compensation + Thermostatic control = Water pump runs Continuous or OnDemand (default) - configurab...
Enable installer mode - 5678 Enter the Space Heating/Cooling menu Enter Pump Operation Mode - Select Continuous or Sample (default) Enter Pump ...
I think it's worth adding here that when you enable the Daikin LWT mode the pump switches from demand/request to sample. That means the pump will cycl...
More like Octopus wanted to fit a Cosy 6 at the end of the garden, avoid planning permission and re-use the tiny airing cupboard. My preference was to...
@toodles Useful reply and because Heat Geek mentioned it in the Daikin MMI vid I didn't do any further checking. Using Grok again to sift through all ...
- 26 Forums
- 2,323 Topics
- 52.1 K Posts
- 481 Online
- 5,979 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Hitachi Yutaki SCombi Heat Pump - Owners
@jamespa I know it’s reached the set point as the set t...
By Sim0n0 , 2 minutes ago
-
RE: Solar panels on side of house to heat water
Not a problem, @toodles; introducing another option bac...
By Majordennisbloodnok , 20 minutes ago
-
RE: Electricity price predictions
Compared with fixed outgoing, that's correct, @toodles,...
By Majordennisbloodnok , 26 minutes ago
-
RE: Replacing my 18 month old Hitachi Yutaki ASHP
@batpred I think I am too! Toodles.
By Toodles , 29 minutes ago
-
RE: Help me keep the faith with my air source heat pump installation
Yesterday it was chilly and the cosy6 had a Cop of 4.3 ...
By AgentGeorge , 1 hour ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Same here! This month 187kw.
By Andris , 2 hours ago
-
RE: Grant Aerona circulation/system pump staying on
@mikefl thanks, so to check is your parameter 4200 set ...
By damonc , 2 hours ago
-
Are Water Companies Delivering Bricks?!
Please look away now if you don’t wish to lose several ...
By Toodles , 2 hours ago
-
@jamespa Ah, they do indeed do firmware updates very oc...
By Toodles , 6 hours ago
-
I’m trying to rule out a fault, could owners of above c...
By Unsure , 6 hours ago
-
RE: Help…my Nibe has faulted again.
Have you actually had a Nibe engineer in or just an ins...
By JamesPa , 7 hours ago
-
RE: Jokes and fun posts about heat pumps and renewables
And I thought I was the one with the taxi on speed dial...
By Majordennisbloodnok , 19 hours ago
-
RE: Heat Pump Training vs. Real-World Installation
Congratulations on passing the course. The observation...
By Max Abbey , 1 day ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
The problem I see with A2A (and I'm interested if there...
By Temperature_Gradient , 1 day ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira vs OVO vs EON.Next vs Boxt
@temperature_gradient I specifically explained to my po...
By Toodles , 1 day ago
-
RE: Grant Aerona Short Cycling
@damonc I was refering to the 'standard' energy sticker...
By MikeFl , 1 day ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
@hcas where do I find Havenwise Support? On...
By Morgan , 1 day ago
-
RE: Should Our Water Circulation Pump Be Configured to Run All The Time?
We recently (Aug 25) had a Grant Aeorana 3 installed un...
By GA3_USR , 2 days ago
-
RE: Configuring third party dongle for Ecodan local control
Thanks, @sheriff-fatman. Happy for you to search any po...
By Majordennisbloodnok , 2 days ago
-
Thanks, @cathoderay. I was aware of some changes to ...
By Majordennisbloodnok , 2 days ago