Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Feb 5, 2024
Things didn't quite go to plan with the install... They can't start this week, but rather next week, so that's a whole extra week without heating. We'...
@alec-morrow Yes the boiler is completely shot, so no point doing a step-by-step change at this point. The installers have confirmed that they'll b...
@alec-morrow Why would you particularly seek out a controller that can control both? I don't foresee running both at once, and I am hoping that now...
I just got back from a lovely warm holiday in a different part of the world to a broken boiler! I turned the heating up a day before we flew back home...
@derek-m Hi Derek, thanks for the post. I thought of that, hence why I thought if the radiator that needs to provide the most heat has 15mm pipes ...
@robl I appeciate the maths here, but I feel that with all the uncertainties stacking with a real life measurement, it might come out worse than the a...
It does sound quite ambitious, but I think it should be fine so long as you take measures to protect yourselves. What happens to the deposit if the ...
The results are in, and using a calorific value of 39.5 (my meter is in m3) and a flow temp of 70C, it started on about 18kW of gas usage, then settle...
28mm pipe can carry 16.8kW of power if the difference in temperature between flow and return is 5C, which it probably is. This means that assuming the...
That's exactly it. I fear that in the ASHP world, if you don't know at least as much as the person selling you it (assuming they're a sales person), y...
I appreciate the vote of confidence! However, I don't think I dare go outside of MCS installations because it gives me recourse if something goes wron...
I guess this is true, but it depends how well the heatpump can modulate its compressor/flow rate. Most, it would appear to me, do not modulate all tha...
- 27 Forums
- 2,793 Topics
- 66 K Posts
- 2,254 Online
- 7,196 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
We have ‘signed on the dotted line’ today for a Panason...
By Toodles , 14 minutes ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
...or it was there and was lost thanks to laziness and ...
By Majordennisbloodnok , 37 minutes ago
-
@bobflux Thank you for your response. I am trying to ...
By RonV. , 39 minutes ago
-
This post is about how I successfully configured a buff...
By Tony.Stolz , 4 hours ago
-
The installer visited yesterday and suggested the noise...
By JamesChatz , 6 hours ago
-
RE: Heat Geek installations: share your experiences
I struggled with this problem as well. An independent t...
By L8Again , 6 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Your house sounds a lot like mine. 2 surveyors each sp...
By JamesPa , 8 hours ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
Thats true only if you do the wrong experiment. Done c...
By JamesPa , 9 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
@temperature_gradient Isn't that just describing a regu...
By Prunus , 9 hours ago
-
RE: battery storage without solar
As of October 1st they need specific qualifications to ...
By EtchedPixels , 22 hours ago
-
RE: Renewables & Heat Pumps in the News
With regards to the BUS grant raid, I gave it more thou...
By ASHP-BOBBA , 22 hours ago
-
RE: Why are ASHP installs so expensive?
The whole system seems to work on the basis of...
By ian33a , 23 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
Good plan. If you can get half hourly meter readings a...
By JamesPa , 1 day ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
@editor Most certainly. The heat pump was an ideal s...
By Abernyte , 1 day ago