Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 5, 2026
@derek-m Yes i have meter for heat pump in fuse box and smart meter outdoors, they pretty similar for past hour usage. No nothing else that would use ...
Thanks lads, house stays warm when up to temp so dont think i have massive heatloss. Attached is ber cert i got for house, think heat loss calc is in ...
With last week of heating, if my daikin is correct im getting cop of 6, which is Great, however im using 2kwh per hour usage or close to it, this is l...
coming to conclusion after talking to hydros too, you cannot run hps at lwt less than 27 in my house anyway. Currently running at 28deg desired, no cy...
Just went into installer, can see compressor starts so far 98 in october, might monitor that tomorrow actually and see how man per hour. Also saw sett...
He didnt quite say but he said he couldn't run low lwt when temps above 8, probably same as me by sounds of things. You suggested running on stats and...
@derek-m I will do tomorrow when herself gone to work, she thinks im having an affair with the hp at this stage. Not sure where i can find compressor...
Looks like a user called hydros was having same issue few years back. Seems at temps above 8 degree you cant have low lwt without excessive cycling.
@derek-m Do you mean compressor stopping and starting? Just keeping an eye on compressor seems to be on for 10 off for 10 approximates. House is 242sq...
flow is stopped also, presume due to delta t being too low. In my situation its never that lwt is getting too high, at most usually 1deg above desired...
When rwt is same or slightly higher then lwt, does that mean floor/house has taken as much energy out of water as possible? Iv set curve lowest so fa...
@rod think lowest i got to was 26@10deg outside. In colder weather will try bit lower, still a lot lower then installer had it originally set to. Appr...
- 26 Forums
- 2,647 Topics
- 61.8 K Posts
- 930 Online
- 7,045 Members
Join Us!
Latest Posts
-
Any readers with an interest in Solar Farm generation i...
By Toodles , 23 minutes ago
-
RE: Heat Pump Operation in Summer - Valliant 7kW
Yup! Summer in Spring. Wonder if Summer will last unt...
By Majordennisbloodnok , 45 minutes ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
I had a look at the manual for the pro and it mentions ...
By Batpred , 2 hours ago
-
RE: Solar Produced vs Home Consumed
It's worth adding that if you have a hot water tank and...
By JamesPa , 2 hours ago
-
RE: Heat Pump Overpromising – What Were You Actually Told Before You Bought?
@editor Sorry Mars, I didn’t see a notification about ...
By Toodles , 3 hours ago
-
RE: Hitachi Heat Pump being replaced with Vaillant
Yes to be configured as a volumiser. The pump is to be...
By trebor12345 , 3 hours ago
-
RE: Anyone concerned about GivEnergy?
So it seems subscription day has finally arrived for Gi...
By TechnoGeek , 4 hours ago
-
RE: How many people are happy with their ASHP and do you believe them?
I agree, and not. Energy prices are a largely politica...
By JamesPa , 7 hours ago
-
Yes, you will need to notify them even if the inverter ...
By Old_Scientist , 7 hours ago
-
RE: Heat Pump Manufacturers Recommending Buffer Tanks
@tony-stolz, I think @jamespa has already covered the h...
By Mars , 20 hours ago
-
@editor "The interesting bit is that many modern invert...
By Singlespeed , 1 day ago
-
RE: Ecodan & MelCloud scheduling
With the prospect of warmer weather this week, I brough...
By downfield , 1 day ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
I reached out to MCS directly last week on this and her...
By Mars , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
My heating developed a really severe case of noise and ...
By JamesPa , 2 days ago