Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 8, 2025
Item 1. is by far the biggest factor IMO. This is from when I let the Ecodan algorithm do its thing unfettered. It's hard to factor in defrosts but ...
Are you sure about that? Really sure? 😆
@cathoderay I did use OAT to predict energy use up to a point; in order to estimate the energy use without setback I looked at other days with the ...
done now, hope it's OK
I'll just record the meter screen of one I have with another phone. I'll do it tomorrow. Kev
Not sure about the app. All looks OK, the meter itself works. I then switch to camera/video but when I press record the dB shown jumps up 10 or so. ...
will do today.
WC is 45@-2 / 30@25 Glycol 25% flow rate is specified as 27l/min (I think I said 25 before) DHW 15:00 other electrical - not much. Washing mac...
I PMd you but this is what I sent: Heat Loss 8.5kW @ -3 OAT LWT 50 Rad output 18500 at DT50 Room temp 21.5 throughout Flow rate not sure I th...
... and when it's all ticking over nicely, one of the Humans in the house hangs the washing on all the radiators!
I'll be interested in what the model makes of my data. I think my ASHP runs reasonably close to the data book; it's a simple set up and it's never ov...
Neither can I and so do I! I'll have a look but I will give up very quickly if it looks too hard! I think you are right in that the air/house are n...
- 27 Forums
- 2,747 Topics
- 64.6 K Posts
- 2,053 Online
- 7,155 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 20 minutes ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 26 minutes ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 9 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 9 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
There is scope for product development here. I for one...
By JamesPa , 11 hours ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 1 day ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 4 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
First time poster here but I can share my experience as...
By SCH , 4 days ago
-
RE: Is it the house or the equipment?
...which, I've found out, is pretty much impossible to ...
By Majordennisbloodnok , 4 days ago
-
RE: Mitsubishi Ecodan FTC6 settings
The Mitsi remote thermostat should not be plugged into ...
By F1p , 5 days ago
-
RE: PV and battery long payback - sense check query
@jamespa I was just commenting on the speed, not sug...
By Batpred , 5 days ago
-
Readers here please note that Derril Water and many oth...
By Transparent , 5 days ago