Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jul 14, 2026
I have only A2W. I am experimenting with my single fancoil and a couple of rads on which computer fans have been mounted, will post the results when ...
@ian33a Ah 2513 vs 1250 makes a big difference. Roughly how many evenings and for how many hours do you reckon the log burner is on for in a year. ...
Sorry I missed that when I first read your post, May I recommend you re-read my post above as I added some information to it, which I am pretty certai...
Its not necessarily always going to put installers off, you need to shop around in the market, different installers have different approaches and some...
And they are right. Currently its almost a fully bespoke exercise for every house, with very little system level productization. There is also a fai...
Pretty good for a heat pump during winter though. Charge at cheap rate, discharge to reduce peak rate imports. Three phase is pretty ra...
...And If the flow is the same both sides the buffer/llh is doing nothing in which case what value is it? A buffer can of course be managed to have ...
@annab @majordennisbloodnok has hit the nail on the head with best next step. Feel free to post their response here for comment. Feel f...
The current consultation for preliminary product specs plug in solar expressly doesn't include batteries BTW. So it looks like we won't get fully leg...
Low loss headers and buffers can, and frequently do, cause 'system distortion', code for mixing of flow and return water thus reducing the flow tempe...
- 26 Forums
- 2,710 Topics
- 63.5 K Posts
- 323 Online
- 7,113 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
What a difference a few degrees make.
With this prolonged spell of warm weather, the ground t...
By Toodles , 2 hours ago
-
RE: Mitsubishi Ecodan FTC6 settings
If there is a setting i must have it set! My Ecodans ha...
By Carpenterstation , 3 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Thank you, I am learning! With these plug in set-ups ...
By Hanno , 3 hours ago
-
RE: New Vaillant aroTHERM Plus
In a word no, I have never fully understood the test co...
By JamesPa , 4 hours ago
-
RE: Electricity price predictions
Thanks @old_scientist, that's good to know. Our battery...
By ChandyKris , 5 hours ago
-
RE: Renewables & Heat Pumps in the News
Be interesting if this results in any wider changes to ...
By Jeff , 10 hours ago
-
Heat Pump Fundamentals For Homeowners
Months in the making. Finally live. I've built an onlin...
By Mars , 21 hours ago
-
If Reform were to win, I suspect that many of the AR7/8...
By Old_Scientist , 22 hours ago
-
RE: HeatPump maintenance in Swindon area?
Sorry I can't but ... it sounds like a job any half dec...
By JamesPa , 2 days ago
-
My contribution is to wonder how your radiators are plu...
By springswood , 2 days ago
-
RE: Powerwall 3 tripping RCDs in powercut
If I were to write a remote diagnostics chart for the P...
By Transparent , 3 days ago
-
RE: GivEnergy inverter tripping due to over-voltage?
possibly interesting to note the latest spreadsheet S...
By Tim441 , 3 days ago
-
RE: Summer heat is becoming the new winter cold in the UK. What are you doing about it?
Our ashp service is booked for a couple of weeks from n...
By Judith , 4 days ago