Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 22, 2026
Topics: 27 / Replies: 5275
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards

OK The actual text of the condition was: Within six weeks of the decision being issued, an ‘at-source’ noise survey at the Air Source Heat Pum...

2 years ago
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards

If you post the link to the planning application I'm happy to take a look.

2 years ago
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards

It will be in the planning application or the supporting documents, which will be (or at least should be) on the LPA's planning portal.

2 years ago
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards

From what I recall The IoA spreadsheet doesn't bother with the last 4 steps in the MCS calculation. These steps are entirely pointless as the pass/fa...

2 years ago
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards

I will try: predicted = (in both cases) as predicted by the documents submitted for the planning application (not sure what they said, but whate...

2 years ago
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards

According to BS 8233 an attenuation of 15dB can be assumed for a wall with a window closed or ajar. So I would say very likely (according to BS 8233)...

2 years ago
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards

Quite possibly true, but that's not the extrapolation the report seeks to make (as I understand it). It seeks to extrapolate from an NR achieved at o...

2 years ago
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards

Of course not. I agree 100% that neither NAPIT nor MCS are the enforcement mechanism. They cannot be, because they are working for installers (a...

2 years ago
Reply
RE: The weakest link – components of an installation team

My solar PV experience was in 2011 and actually very good in terms of the design/installation itself. It was done end to end by one guy running his o...

2 years ago
Reply
RE: Misleading government advertising

@derek-m Fair cop (or COP?). That just shows how easy it is to interpret something in a way that one expects not read what it actually says. This is...

3 years ago
Reply
RE: Misleading government advertising

Does it conflate the two, the bit about heat pumps (reproduced below) talks about energy efficiency not cost savings so far as I read it. I guess you...

3 years ago
Reply
RE: Air Source Heat Pump Policies – MCS Planning Standards