Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 6, 2026
OK so thinking about this further, a compliant plug in inverter (as distinct from one that is permanently wired) must shut down on loss of mains withi...
That all makes sense thanks, albeit that it is not exactly a quotable reference which is no fault of yours. Presumably somewhere in this you also s...
@editor would Indevolt like to comment on the shut down time of their inverter in the case of mains failure/very severe undervoltage and/or the risk t...
OK thanks thats clear now, but not an issue that particularly relates to plug in solar then and not particularly a safety issue, more an issue of func...
OK thats an important qualification. The BEEMA technical bulletin seems to suggest that both RCDs and RCBOs could be affected, but the IET write up h...
Yes I know. Obviously you only speak to helpful electricians. Some of those I have spoken to would use the 'old cu - no parts available' excuse notw...
Thanks, that makes sense - sort of - although since the test button disconnects the supply surely the same could have been achieved (with one less com...
Yes I know that, but I thought the problem you described was caused by the RCD function of an RCBO (ie if it fails it continues to operate as an MCB b...
As I understand it the part that would fail is a solenoid coil and the failure mechanism is getting too hot because its energised for too long. If t...
Thanks and noted (but did you mean battery rather than EV, EV is currently unidirectional - or was the comment meant to refer to possible pulsating DC...
Maybe, but if you have an older CU (like mine - about 15 years) then the components may not be available. You can get some for mine secondhand only, ...
- 27 Forums
- 2,736 Topics
- 64.3 K Posts
- 1,545 Online
- 7,141 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Indevolt Batteries UK Support & Info Thread
You'll have to excuse me, this is all new to me and I s...
By BlizzardGreen , 5 hours ago
-
RE: PV and battery long payback - sense check query
@old_scientist I have now drafted 2 replies - both have...
By DavidB , 9 hours ago
-
Grant Aerona Air to Water R290 6.5 kW - Quiet Mark and Silent Running
Helping a family member with brand new installation of ...
By Chris66 , 14 hours ago
-
RE: Can I start an argument about buffer tanks please? 🙂
Assume flow from the heat source is higher than flow to...
By bobflux , 18 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: adrian Manufacturer: Appliandirect.co....
By Adrian , 21 hours ago
-
RE: Acond heat pump failed after four years - diagnostic quote £940 plus VAT
@downfield Thank you Downfield. This sounds potenti...
By Mia , 1 day ago
-
RE: Digest of UK Energy Statistics
@jeff Yes my brother in Oz told me of that charge year...
By Jancold , 1 day ago
-
RE: Love veg, hate watering cans
My dear daughter came for a bath and was given clear (I...
By Jancold , 1 day ago
-
RE: Questions about A2A for heating as well as cooling
@ashp-bobba ah that's good to know, I'll get in contact...
By donciccio , 2 days ago
-
RE: Aircon - in listed buildings
@etchedpixels thanks for giving such a full and helpful...
By GrahamF , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist The service engineer powered down the ex...
By Papahuhu , 3 days ago
-
RE: Issue with Samsung Cascade System
@jamespa It's a funny system, but was out only option l...
By Renewables345 , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Thanks, I like the chart, very helpful and this will de...
By baroquebank , 3 days ago