Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 4, 2026
@rob-of-york Great data and analysis. Im personally convinced that, intelligently used, this is a sound way to assess heat loss. FWIW h...
Great. You just need to find a way of cranking up your circulator (if necessary) until either the target flow rate is reached or its too noisy, or pl...
There may be a 'max temp for heating' parameter. Alternatively you could extrapolate the curve to a higher OAT point and set the T4H2 parameters acco...
Could be, but of course that will cause the IAT to rise. There again you might, quite possibly do, open the door/windows to compensate. I set my min...
There arent many of these hitachi pumps around here so you may not get an answer. I had a not dissimilar fault with my Vaillant albeit I did get a (...
No it cant, but it could be a (material) fixed or quasi-fixed consumption by the heat pump, or a variable loss elsewhere in the pipework (eg the PHE) ...
Absolutely agree. When I did my heat loss determination I averaged over a day and found that the fit was better, albeit only marginally, if...
It may make sense but its not as expected, it should be negative. You are plotting delivered energy to the house vs DT and if there is a positive con...
I think trying to deduce flow rate from an instantaneous measurement of deltaT on a system where you dont know the house loss is a stretch to say the ...
That may not be the case, because its not necessarily the case that PWM = 100% means that the flow rate is 1200l/hr as depending on the pump character...
I thought so Whether you have to take them into account or not depends on the thing you are measuring/the calculation you are doing! A simple drawi...
Or where you can fix the pwm% as you can eg with Vaullant and doubtless others I'm now confused. I thought that there was no point in your syst...
- 27 Forums
- 2,783 Topics
- 65.6 K Posts
- 2,245 Online
- 7,187 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Indevolt Batteries UK Support & Info Thread
I've got a podcast recording scheduled this week where ...
By Mars , 8 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
I’m a little late posting this, but it’s genuinely one ...
By Mars , 8 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Ah, that makes sense when a combi is in place. The boil...
By Batpred , 11 hours ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
@bobflux Thanks, that gives me something to check the i...
By Paul1098 , 11 hours ago
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
Without doing some research I can't immediately answer ...
By JamesPa , 13 hours ago
-
RE: Tesla Powerwall (2) Calibration Cycles
For Powerwall calibration, avoid forcing repeated deep ...
By EnergyStorageTech , 20 hours ago
-
Over the years, due to the non barrier PEX underfloor h...
By bobflux , 1 day ago
-
RE: Getting closer to a finished Haier system
All the 45° elbows required for getting the primaries i...
By Singlespeed , 1 day ago
-
RE: battery storage without solar
Indeed, current on the grid input = current used for ch...
By bobflux , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu @papahuhu A lot of tears and sweat went into ...
By Andris , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
We have the same problem, 12 mature trees clip the morn...
By Papahuhu , 4 days ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
I had a battery and inverter installed a while ago, my ...
By Batpred , 4 days ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@ltron2 The EPC on our house is A-92, however that i...
By Rob of York , 4 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
The layout is confusing - much better like this: We b...
By downfield , 5 days ago
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
My experience, backed up by opinions from various frien...
By Majordennisbloodnok , 5 days ago