Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 4, 2026
Topics: 27 / Replies: 5447
Reply
RE: Adventures in heat loss calculations

@rob-of-york   Great data and analysis. Im personally convinced that, intelligently used, this is a sound way to assess heat loss. FWIW h...

4 weeks ago
Reply
RE: Next steps on my ASHP journey: Radiators and Pipework

Great. You just need to find a way of cranking up your circulator (if necessary) until either the target flow rate is reached or its too noisy, or pl...

4 weeks ago
Reply
RE: Where heat loss surveys seem to go against practical reality

There may be a 'max temp for heating' parameter. Alternatively you could extrapolate the curve to a higher OAT point and set the T4H2 parameters acco...

4 weeks ago
Reply
RE: Where heat loss surveys seem to go against practical reality

Could be, but of course that will cause the IAT to rise. There again you might, quite possibly do, open the door/windows to compensate. I set my min...

4 weeks ago
Reply
RE: Yutaki M (RHUE-3AVHN) + XEK23232A System Controller — DHW reheat randomly fails to start, no fault code, fixed only by power-cycling controller

There arent many of these hitachi pumps around here so you may not get an answer. I had a not dissimilar fault with my Vaillant albeit I did get a (...

4 weeks ago
Reply
RE: Where heat loss surveys seem to go against practical reality

No it cant, but it could be a (material) fixed or quasi-fixed consumption by the heat pump, or a variable loss elsewhere in the pipework (eg the PHE) ...

4 weeks ago
Reply
RE: Where heat loss surveys seem to go against practical reality

  Absolutely agree. When I did my heat loss determination I averaged over a day and found that the fit was better, albeit only marginally, if...

4 weeks ago
Reply
RE: Where heat loss surveys seem to go against practical reality

It may make sense but its not as expected, it should be negative. You are plotting delivered energy to the house vs DT and if there is a positive con...

4 weeks ago
Reply
RE: Next steps on my ASHP journey: Radiators and Pipework

I think trying to deduce flow rate from an instantaneous measurement of deltaT on a system where you dont know the house loss is a stretch to say the ...

4 weeks ago
Reply
RE: Next steps on my ASHP journey: Radiators and Pipework

That may not be the case, because its not necessarily the case that PWM = 100% means that the flow rate is 1200l/hr as depending on the pump character...

4 weeks ago
Reply
RE: Where heat loss surveys seem to go against practical reality

I thought so Whether you have to take them into account or not depends on the thing you are measuring/the calculation you are doing! A simple drawi...

4 weeks ago
Reply
RE: Next steps on my ASHP journey: Radiators and Pipework

Or where you can fix the pwm% as you can eg with Vaullant and doubtless others I'm now confused. I thought that there was no point in your syst...

4 weeks ago
Page 10 / 457
Share:

SPONSORS

Join Us!

Installer Finder

Degrees of Separation

Latest Posts

SPONSORS

Members Online

 No online members at the moment

Click to access the login or register cheese
Protected By
Shield Security PRO