Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

HydroS
@hydros
Member
Estimable Member
Joined: Dec 17, 2021
Last seen: Oct 16, 2024
Topics: 2 / Replies: 57
Reply
RE: ASHP Cycling On/Off - Is it an issue?

@saenergy I've altered the curve. Currently running at 28-29C today and the house is plenty warm enough. Would bigger radiators result in an improv...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue?

@saenergy Thanks for the pointers. Regarding the bypass valve, I assume winding it in will effectively shut it off for now would it? The diver...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue?

@derek-m & @kev-m Thanks for looking over the report. I was going around in circles a bit with the report too but didn't know if it was me and m...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue?

@saenergy The auto bypass is located just after the 3 port valve, before any of the radiators. A quick google search suggests it should be located ...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue

I have posted a link to the report, it's just not showing as one. I'll insert it properly here as I can't edit my original post.

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue

@derek-m forgot to add - agreed on scheduling the time of the hot water run, I did find that improved things. I've already got mine setup for late aft...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue

@heat-pump-newbie electricity usage is about the same for a comparable day, but heat output is higher, so that's a win. But I've noticed the compresso...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue

@kev-m Yes, the COP is for both. I didn't use much hot water yesterday, so most of the demand was on the heating. See screenshot below for the last...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue

@derek-m The cycling is only occurring at outside temperatures above about 8C so probably nothing to worry about. COP for yesterday was 3.18, not b...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue

@derek-m Still good news I think. I've had about a week of running using the weather compensation curve. The house is definitely warmer, almost too...

4 years ago
Reply
RE: ASHP Cycling On/Off - Is it an issue

@derek-m thanks again for the info. So I sat with the heat pump controller for two hours this evening recording data every five minutes, I can post ...

4 years ago
Reply
RE: Rate your air source heat pump installer