Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 1, 2025
@gunboatdiplomat The £2-3000.00 extra cost could very easily be eaten up in a few months, Last year I repaired a system with an average winter spend o...
I am not sure you realise the implication of design compromise. It can quite easily double your current heating bill, I have seen it many times. Would...
@lucia All BG installations are now installed using my open zome, high performing designs. All installations, weather installed by subcontractors, or ...
Caution everyone, this manual stipulates the installation of a buffer tank, so, the promised guaranty of supplying sufficient heat, may come at a very...
@ecobaker probably not
Yes, just make sure you have the correct flow rate at all times.
@bontwoody Maybe they have corrected it, I hope so.
@toodles Spot on, mostly from installers therefore end users, someone has to pay for it. However, that is only a very small part of the cost. I ran ...
@bontwoody That flow temperature is pretty close to 45 Deg C (43 deg C), it could be sensor drift that is causing the activation, it is clear that it ...
MCS and Heat Geek are not the same thing. MCS is a standard that any Heat Geek, or any other installer, has to abide by. It is not an installation sta...
@ecobaker They work reasonably well on open zone, just make sure you always have the minimum flow rate. Attached is a manual with the open zone prog...
@toodles The Heat Geek brand is just that, a commercial, moneymaking brand.
- 27 Forums
- 2,783 Topics
- 65.6 K Posts
- 1,134 Online
- 7,187 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: How should the Boiler Upgrade Scheme be reformed?
Yes, their gas typically costs twice ours and electrici...
By Batpred , 1 hour ago
-
Over the years, due to the non barrier PEX underfloor h...
By bobflux , 2 hours ago
-
RE: Getting closer to a finished Haier system
All the 45° elbows required for getting the primaries i...
By Singlespeed , 3 hours ago
-
RE: Tesla Powerwall (2) Calibration Cycles
@papahuhu Likewise, the main ‘extra’ relates to TOU tar...
By Toodles , 9 hours ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
That sounds like a better approach (being able to see a...
By cathodeRay , 1 day ago
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
Thanks for the reference @jamespa I can't see any te...
By Transparent , 1 day ago
-
RE: battery storage without solar
Indeed, current on the grid input = current used for ch...
By bobflux , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu @papahuhu A lot of tears and sweat went into ...
By Andris , 1 day ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
We have the same problem, 12 mature trees clip the morn...
By Papahuhu , 2 days ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
I had a battery and inverter installed a while ago, my ...
By Batpred , 2 days ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@ltron2 The EPC on our house is A-92, however that i...
By Rob of York , 2 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
The layout is confusing - much better like this: We b...
By downfield , 4 days ago
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
My experience, backed up by opinions from various frien...
By Majordennisbloodnok , 4 days ago
-
RE: Analysis of the economics of switching to an A2W ASHP compared to other heat sources
I had a meeting today with a company based out of Swede...
By Mars , 4 days ago
-
RE: Review your electricity provider
We were with Octopus in our old house and it was fault...
By ian33a , 4 days ago