Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 1, 2025
@markc The installers put buffer tanks in to stop low flow errors occurring with their badly designed heating systems. It covers their inadequacies, a...
@derek-m You are correct for old fixed compressor units. Most manufacturers recommend 10 litres per KW from flowing volume for a heat pump. Most new i...
@markc That valve you have there is a low flow high-temperature valve, you are throttling your system, effectively it cannot breathe. You need to chan...
@markc You are right, I think Mars needs to organize the forum a bit better.
@batalto As Suspected, It is a fit and forget configuration designed by Freedom Heat Pumps to prevent call backs due to the inability of their install...
Actually there has been little change from prior to MCS being launced appart from an indcrease in the price of installations by 2000-3000 pounds, ther...
@editor Actually Mars, it would make more financial sense to get your system fixed, you would not drive your car with flat tyres. There is not much ...
@batalto Unfortunately, if you do not do things properly, it may not work. Like trying to drive a car without pumping up the tyres. It is all there bu...
@derek-m I agree, unfortunately this industry is self-destructing and nobody seems to care, it is very frustrating. I hope, someone will read my con...
@batalto The pumps are more than likely too small and not capable of transferring sufficient water to deliver the heat. However, the buffer thank is...
@batalto Is it a 4 pipe one with a pump pumping round your radiators?
@batalto Do you have a buffer tank or system seperation?
- 26 Forums
- 2,677 Topics
- 62.6 K Posts
- 177 Online
- 7,090 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Heat pump installation quotations
That will be absolutely murdering your energy efficienc...
By EtchedPixels , 5 hours ago
-
RE: Harvest Thermal - ASHP with a smart thermal battery
The cooling side works much better if you can figure ou...
By EtchedPixels , 5 hours ago
-
Floor standing brackets for K3 rads
My neighbour is a plumber and said I would need to fit ...
By Singlespeed , 6 hours ago
-
After an intense recode, I’m pleased to announce that w...
By Mars , 6 hours ago
-
Why do you want to maintain a specific deltaT? The out...
By JamesPa , 8 hours ago
-
Hopefully this will answer your question. To...
By ASHP-BOBBA , 8 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
I would be interested to find out if others do this and...
By ASHP-BOBBA , 8 hours ago
-
Don't you dare. You just carry on as you are; as @batpr...
By Majordennisbloodnok , 10 hours ago
-
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump
@ragtime27 some rooms in our house only have one place ...
By Judith , 10 hours ago
-
RE: Several AC coupled batteries
That is a good point, a manufacturers can stop trading,...
By Batpred , 14 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Hi @hanno - good question. The range of hybrid invert...
By Transparent , 15 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent the inverter was installed in 2021 and afa...
By Tim441 , 15 hours ago
-
RE: Say hello and introduce yourself
I hope so, @toodles. It's not often that we see a situa...
By Majordennisbloodnok , 19 hours ago
-
RE: Electricity price predictions
Good point, I do expect the bonus of putting my energy ...
By Batpred , 2 days ago