@toodles All those factors might result in a lot more heat being required, it can still be delivered in a very efficient way. Lack of efficiency seems...
I think @technogeek is looking at a Vaillant which does, I believe, present a figure for the 'free' heat generated by the pump, so the 'paid-for' inpu...
If you really were getting a COP of 6 in Feb using WC mode then I'd be wondering if there is any benefit to changing to AA mode if it proves to be les...
Heat loss surveys are always going to be guesswork – even more so when you don't have evaluated materials and construction methods. Heat loss via air ...
@sunandair The Ecodans just do not have a meter-grade electricity monitoring capacity. There is an over-estimation of the daily consumption that is...
I think this notion of an 'optimal' install is something of a chimera. Every installation is different, and the majority of forum users have experienc...
The last picture is the flow meter, the other two are of the tank thermistor in its pocket. The flow and return thermistors should be on the main pipe...
I would look first at the placement of the thermistor measuring the flow temperature. I am going to assume you have an Ecodan cyclinder too, in which ...
Your house loses heat 24hrs a day – if you heat the house for only some of those hours then you have to replace the lost heat as well, which if you ha...
The surplus consumption appears even when the heating is off over the summer, sometimes weirdly high, ie 3kWh - and though there is proportional relat...
@davidalgarve My surplus power 'consumed' last year was around 630kWh, so around 1.75kWh every day. Some fairly random variation either side of this...
@jaket I think the flat bottom to the return temp shows how the slab temperature is preventing anymore heat being dropped from the circulation in t...
- 26 Forums
- 2,323 Topics
- 52.1 K Posts
- 195 Online
- 5,979 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Help me keep the faith with my air source heat pump installation
The engineer came yesterday and as the rooms were ok te...
By AdamK , 4 minutes ago
-
RE: Electricity price predictions
🤣 One way to think about it is that they real...
By Batpred , 4 minutes ago
-
RE: Hitachi Yutaki SCombi Heat Pump - Owners
@jamespa My experience is that local 'old school' plumb...
By Sim0n0 , 28 minutes ago
-
RE: Replacing my 18 month old Hitachi Yutaki ASHP
@jamespa Can I check something that I done some weeks a...
By trebor12345 , 1 hour ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
The problem I see with A2A (and I'm interested if there...
By Temperature_Gradient , 2 hours ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira vs OVO vs EON.Next vs Boxt
@temperature_gradient I specifically explained to my po...
By Toodles , 2 hours ago
-
RE: Grant Aerona Short Cycling
@damonc I was refering to the 'standard' energy sticker...
By MikeFl , 5 hours ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
@hcas where do I find Havenwise Support? On...
By Morgan , 6 hours ago
-
RE: Should Our Water Circulation Pump Be Configured to Run All The Time?
We recently (Aug 25) had a Grant Aeorana 3 installed un...
By GA3_USR , 11 hours ago
-
RE: Grant Aerona circulation/system pump staying on
My AERONA 3 circulation pump runs constantly whatever t...
By damonc , 19 hours ago
-
RE: Configuring third party dongle for Ecodan local control
Thanks, @sheriff-fatman. Happy for you to search any po...
By Majordennisbloodnok , 22 hours ago
-
Thanks, @cathoderay. I was aware of some changes to ...
By Majordennisbloodnok , 22 hours ago
-
RE: Trying to understand my Nibe F1245
@greenlight Many thanks for the information, it's set m...
By Chris12 , 1 day ago
-
This is what I answered, I really have no hope: "......
By Batpred , 2 days ago
-
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@andrewj oh yes they offer Daikin 8kW, they tried to fo...
By AgentGeorge , 2 days ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@majordennisbloodnok Good point! Just in case anyone re...
By Batpred , 2 days ago
-
RE: Benefits of an extra horizontal loop for GSHP
A correct sized collector is all you need. Saying this,...
By greenlight , 2 days ago
-