SITREP 1. Evening charging seems fixed. Adjusting the shutdown, low battery and restart fixed that. Apparentl y the inverter wil...
Grid Charge in battery setting is the 1 I suspect. Note - tried many setting to get it to stop charging this evening. I don't think I'd bu...
Ok, I can handle that - will set for voltage mode and try. Regarding the evening charging - how do I combat that? Under battery settings, Grid...
@robl So... The Sunsynk is not a intuitive firmware. That's is putting it mildly. The exchange between it and the battery, appears to be gettin...
@robl Cheers for the screens dump - really useful. Battery charged fine overnight. Raises some questions, Your shutdown, low and restart are 0%, 1% ...
Seems the timer was the issue, I had time 1 set wrong. Worked @08:00 and all day so far.
The manual says 80%DOD - for 3500 cycles My interpretation of that is 10%~90%. On other forums, the common consensus is 20%~100% = 80%DOD This i...
So close..... @robl My battery discharged all day lovely got to 20:30 before it ran out - 20%SOC once it hit 20% - the Sunsynk immediat...
@adrianmc Ive it setup 90% ~ 10% - to match the 80% DOD rate that is listed in the Fogstar manual.
@robl And as everyone said and expected, the CT cabling was the wrong way round. The manual is awful in that section, basically guess the colou...
So life got in the way, as it normally does - I have eventually got onto it and installed it - following regs as best i can. MCB Surge protect...
@misterb @editor So it has actually arrived. Will post a decent update after I attempt an install this weekend.
- 26 Forums
- 2,171 Topics
- 47.8 K Posts
- 29 Online
- 5,744 Members
Podcast Picks
Latest Posts
-
RE: Powerwall 3 or Myenergi or something else?
Many of those tariffs are simple time of use tariffs, w...
By Temperature_Gradient , 7 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
Yes thats the whole point of the flexis as regards tran...
By JamesPa , 7 hours ago
-
So far as I can tell designing for DT5, which is 'the n...
By JamesPa , 8 hours ago
-
Mitsu PAR-WT60R Wireless Controller - options
I hope I have satisfactorily installed the above wirele...
By DavidAlgarve , 10 hours ago
-
WC curve best discovered by experiment anyway as any lo...
By JamesPa , 14 hours ago
-
RE: Big Changes Coming to Our Heat Pump System
@editor your engineer's attitude is truly horrifying. ...
By GrahamF , 1 day ago
-
RE: How to choose Towel Rails for an ASHP
@rob-nezard yes absolutely. Here is the link and a pho...
By GrahamF , 1 day ago
-
@mixergy Thanks for the update, I would appreciate some...
By bontwoody , 1 day ago
-
RE: Is Your Broadband Router the Weak Link in Your High-Tech Home?
Unfortunately I'm not that well connected 😂 ...
By Scalextrix , 2 days ago
-
RE: A Customer's Lessons Learnt from a Heat Pump Installation in a Large House
It is interesting to see what our new Grant Aerona 290 ...
By GrahamF , 2 days ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
I've never physically seen it, but I seem to recall som...
By cathodeRay , 2 days ago
-
RE: Midea ASHP – how to set weather compensation
I noticed that too and thought the same thing, but then...
By cathodeRay , 2 days ago
-
RE: Ya can’t win! It is S*d’s Law!
@old_scientist If IOF is still running next late spring...
By Toodles , 2 days ago
-
RE: Electricity price predictions
Those of you on Agile will do well tomorrow; there are ...
By Toodles , 2 days ago
-
RE: Who’s Caved and Switched the Heating On Already?
We've been running our Ecodan system, installed in June...
By Sheriff Fatman , 3 days ago
-
Ok. Two schools of thought. The first is to run the ...
By JamesPa , 3 days ago
-
@drei Willing as I am to help, I don't think I'm yet ...
By JamesPa , 3 days ago
-
Selling 5 year old ASHP & Gas Combi Boiler - £590
Selling a 5-year-old Daikin Altherma Hybrid Air Source ...
By Paul G , 4 days ago
-
RE: Is a Valliant Inline 6kW heater a BUS buster?
Much of that is true in principle, but its not likely t...
By JamesPa , 5 days ago