Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 13, 2025
@skd That is a good point but it is only on FTC 6 it’s not on FTC5 or at least I don’t have it on my FTC5
@derek-m At current mild OAT its all run from battery charged off-peak supplemented with solar if required, I run house/heatpump/charge battery from t...
@derek-m turns on at 21C off at 22C, its came on at 1.30pm today will probably hit 22C around 6.30 so 5 hours run time no cycling at 1kwh. Once its ...
@rich I have an 8.5kw ecodan to keep cycling to 1 per hour at any temp below 10C I need to run at 32C, anything less leads to a lot of cycling. That...
Nice work - my system is almost identical to yours, I look forward to seeing if you get any efficiency benefits.
That will be because it was warmer outside more heat in the outside air means the heat pump has to work less and therefore more cycling.
Welcome it sounds like your heatpump is too big for your property and as you have found out over zoned. It sounds like you have it running as good a...
@jaket The heat pump can only either heat hot water or supply the central heating, it cannot do both at the same time. It looks like your hot water ...
@sunandair could you post a link to the databook please
@sunandair I agree, I remembered this yesterday then forgot again, thanks for posting
@jaket as the unit is cycling so much you wont get a stable dT from the brief periods its stable it looks like it would be 35C flow 32 return so a dT ...
@jaket Hi- your getting there its cycling less than it was, increase the temp further and see if you can get rid of it.
- 26 Forums
- 2,714 Topics
- 63.6 K Posts
- 414 Online
- 7,114 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Mitsubishi Ecodan FTC6 settings
While @F1p's dongles are great, the FTC can do this its...
By RobS , 26 minutes ago
-
RE: Samsung heat pump - data cable issue
If it's a data cable, current will be minuscule, voltag...
By bobflux , 1 hour ago
-
RE: Rate the quality of your heat pump design and installation
I'm kind of at the end of my heat pump installation now...
By JandP , 6 hours ago
-
RE: MCS Quality Audit – Has Anyone Had One? Did It Lead to Remediation?
I got hit with an RHI audit in 2022. It was far from c...
By Abernyte , 7 hours ago
-
RE: Electricity price predictions
@papahuhu Groucho Marx had something to say about no...
By Toodles , 9 hours ago
-
Given the way radiation and convection effects don't wo...
By Majordennisbloodnok , 11 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@jamespa haha very true, although the engineer yesterda...
By swwils , 14 hours ago
-
RE: Vaillant Arotherm Pro vs new Plus
One of the test modes in the installer menu forces it t...
By JamesPa , 1 day ago
-
RE: What a difference a few degrees make.
Wow. Having accepted the challenge, I ran the cold tap ...
By Old_Scientist , 1 day ago
-
RE: HeatPump maintenance in Swindon area?
@vince31 have you tried using our finder:/p>
By Mars , 1 day ago
-
Looking for beta testers for a new homeowner heat pump tool
Over the past few months I've been building a brand new...
By Mars , 1 day ago
-
-
RE: Indevolt Batteries UK Support & Info Thread
It depends on how you configure it via the app. The ma...
By JamesPa , 1 day ago
-
RE: Renewables & Heat Pumps in the News
Be interesting if this results in any wider changes to ...
By Jeff , 2 days ago