I'm no joking, put some ice(make an (big enough)ice cube with a string in it) on the air temperature sensor at the back of the unit, and watch what it...
That's why I've posted the link of the system with the date in the picture.
I can only say that one comment regarding the AA not needing the WC curve to be set, stems from this mitsubishi document that I've shared(photo as wel...
edit wrong info, maybe this?
Use translate in browser. 1./p> 2./p> 3/p> 3. 4./p> 5./p>
New Ecodan 11kW UFH, similar data.
@derek-m if you skim through this Samsung doc, you will see details how a double compressor "heat pump"/AC works, some of this data is pointless to an...
@bontwoody did you size it right? last 8-9 days, zero cycling.
If your flow rate is about 25l-30l/m then that would be a normal behavior given that you are reheating an empty UFH. This 6kW ecodan was doing somet...
- 27 Forums
- 2,475 Topics
- 57 K Posts
- 226 Online
- 6,165 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Help me keep the faith with my air source heat pump installation
Got Vaillant coming on Monday. Any tips on how to get t...
By AdamK , 5 hours ago
-
RE: High Temp Heat Pumps for fast warm-up of house
Several years ago we went away for a weekend in the mid...
By JohnnyB , 8 hours ago
-
@jamespa Many thanks NAPIT have misinformed me again. 2...
By Bart , 9 hours ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
This is the vision I bought into when I signed the cont...
By razz , 9 hours ago
-
RE: Rate the quality of your heat pump design and installation
@technogeek, you raise several fair points. You’re abs...
By Mars , 10 hours ago
-
@sune, will you be easy to identify and are you still s...
By Mars , 10 hours ago
-
RE: Gaslighting in the heat pump industry – has anyone else experienced this?
What’s remarkable from this very short thread is just h...
By Mars , 11 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
@benson I am using the met.no forecast integration and ...
By Grantmethestrength , 11 hours ago
-
RE: Setback savings - fact or fiction?
The system I looked at and used the charts from was a M...
By cathodeRay , 13 hours ago
-
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer
er, if you do this how will the heat pump ever know to ...
By JamesPa , 14 hours ago
-
RE: What a Bad Heat Pump Installation Looks Like
@editor I can just about make the badges from the front...
By idemportent , 14 hours ago
-
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump
Btw, fixing your system so the underfloor heating is wo...
By Adrian , 16 hours ago
-
RE: Optimising LG Therma V R32 using AI
On the main controller you can easily press + or - u...
By Tim441 , 18 hours ago
-
RE: If a heat pump can only heat DHW to 50C then what? Issue with 18KW Heliotherm heat pump
@errmm, have the original installers not come out to ha...
By Mars , 23 hours ago
-
RE: Vaillant Tech Support Flagged Low DT: UFH Return Cold, Suspected Zero Flow
@editor thanks for the tips which I will try before cal...
By DavidB , 1 day ago
-
RE: Daikin 6kw setup with Dixell controller
@jamespa Many thanks for your reply, a very detailed an...
By CraigH , 1 day ago
-
RE: Exploring the role of alternative clean heating solutions - Government Consultation
Despite reservations, I found some time to respond to t...
By Rusty , 1 day ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
@crankplus, nope, still not, and I've followed up with ...
By Mars , 1 day ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@agentgeorge Probably, but temperature change at -10 ha...
By AndrewJ , 2 days ago
-
RE: External wall insulation - your experience
To be clear, my experience was very positive. The journ...
By Batpred , 2 days ago