RE: Mitsubishi Ecodan R290 10kW performance

@ecoste From the graphs I wonder why its heating water DHW to 55C from midnight, is that when you want it super hot? Should take around 45 minutes to ...

1 month ago
Reply
RE: Midea ASHP – how to set weather compensation

@batalto Looks fine to me too, then I noticed the date! these old posts crop up too often then if you reply often get a message saying it was sorted s...

1 month ago
Reply
RE: Air to Air Heat Pumps

@springswood we install these nationwide and I have them in my own home. they are super efficient (nothing cheaper) and cost effective to purchase. Th...

1 month ago
Reply
RE: Designing my house system with a mix of air to air and air to water

The A2A would be mostly if not all free if you have so much PV and a large battery. Mine is most of the year. It'll be cheaper and far quicker to work...

1 month ago
Reply
RE: Replacing knackered oil boiler with Samsung ASHP - Perthshire

@dowallydrifter Sounds like legionella cycle, normally on a Tuesday if the installer didn't change it. Turn the water off if not using it when away. T...

2 months ago
Reply
RE: Newbie: utterly confused with my Mitsubishi Zubadan air source heat pump running on 55C set flow temperature

It'll bring on electric back up heaters if at 55C as they'll work quicker in the winter. Not sure about old ME units but Daikin had a 6 or 9kW back up...

2 months ago
Reply
RE: Large heat pump options for church building

We install mostly A2A for churches and village halls, often due to little use and quick heating required. They will always work out substantially chea...

2 months ago
Reply
RE: Should Our Water Circulation Pump Be Configured to Run All The Time?

@grahamf Okay, I assumed you'd had an answer from Grants, I've not come across a Grant HP with its own pump not stopping. Their tech support is good s...

2 months ago
Reply
RE: Should Our Water Circulation Pump Be Configured to Run All The Time?

This is often a problem when units are installed under a grant scheme. Some have two or three pumps running all the time! They should always be contro...

2 months ago
Reply
RE: Renewables & Heat Pumps in the News

@batpred We run our aircon in the summer not just to keep fresh and have a pleasant indoor temperature, but to use up some of the spare energy we gene...

2 months ago
Reply
RE: Are We Sleepwalking Into Another Race to the Bottom?

It a ridiculous approach, impossible to have zero disrupt, that means as you say nothing is upgraded, just chuck in another poorly working heat pump. ...

2 months ago
Reply
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time

@lch07 They must be wired into the Samsung control panel so they're controlled by it, hopefully thats what your guy has now done.

2 months ago