Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

davidnolan22
@davidnolan22
Member
Estimable Member
Joined: Jan 15, 2025
Last seen: Jan 7, 2026
Topics: 0 / Replies: 136
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

@jamespa thanks again. It makes sense. Before the new bigger LLH, I had a 35mm piped distribution header. There was no blending there, only when I put...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

Hi Gary, Yes, I think I’m getting the hang of it and whats gone on this winter. And yes, during the cold snap previously there was not enough en...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

That’s a really thoughtful reply. Thank you. It’s a great help. lots to ponder. My view has been consistently that i don’t need much more than 35 t...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

I mean, if I put in 45 on fixed flow as the flow temp, open all Zones and leave it, it will never get there, spends hours ( I’m mainly UFH in screed)...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

@jamespa What controls the pumps Wireless stats control the rad and 3rd party stats the UFH, all of them calling for heat all the time Are you ...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

@jamespa At the minute I have all stats turned to max and running weather compensation. Its running 24/7. all the rads are fully open, nothing is s...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

@gary yeah, I have one wireless stat doing the rads, and then 3rd party ones which i just have turned to max now as they are a total pain in the ass.

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

@jamespa House is 258m2, recently renovated. done a good as job as possible with insulation: stone build but most external walls old and new have ...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

Just to update here on the above. My installers came to hopeful sort my heat pump system out. They swapped a piped header for a bigger low loss heade...

1 year ago
Reply
RE: Ecodan 2 zone setup issues

@michaelsimpsonuk hi, I’m still aware that this isn’t your heating system: it’s your landlords. I’d tell them your concerns or move out.

1 year ago
Reply
RE: Ecodan 2 zone setup issues

That’s quite expensive, but, to put into context. My heat loss is about 9 to 10kw at 0 degrees. And with my high thermal mass, I can only run my house...

1 year ago
Reply
RE: Ecodan 2 zone setup issues

On that point, I’d agree. I’ve a 260m2 retro fit. Parts of it are 18th century cottage. I’ve got 11.2 kw. It’s not got lots of spare capacity, but see...

1 year ago