So just for completeness here is may last update on this topic regarding the cost effectiveness of adding another 5kWh to my battery module. Betwe...
@pooneil Hi. I do understand that this can be confusing at first and as a landlord myself I understand your need to get this sorted. Your idea of se...
@jamespa You have got me thinking now, I think it turns off above the top value as I used to have my controller in the hall and Im pretty sure it swit...
@pooneil OK, I dont think you have really got the understanding of how weather compensation works yet. The 17C and -2C are markers for when the heat...
@heatgeek I see what you mean, I couldnt read the figures when looking at my phone screen and I assumed the gap was a DT of 5C which it has been throu...
@pooneil Here are my settings. Keep 201* at 17C and -2C and just lower 202* a little. Notice in 202* at the top it says "For WL1 Heat" and my 2041 set...
@heatgeek Isnt the DT steady at 5C? The only time I can percieve it isnt is when starting up and its trying to get to temperature. The flow and return...
@heatgeek No. I can confirm it does have the facility for PWM control. Just an appropriate pump and a lead is needed
@heatgeek Hi, its run on pure WC, open loop system with a PWM controlled pump. The controller is in the living room and set to stop the heat pump if t...
@pooneil Unfortunately the controller is wired with a two wire cable. It is measuring your internal temperature so if its in a cupboard, thats not ide...
@pooneil That can be moved quite easily into another room if necessary. Mine acts as a limiter in case the room gets too hot because of solar gain and...
- 26 Forums
- 2,342 Topics
- 53 K Posts
- 523 Online
- 6,000 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Poll for Time of Use, tariffs, technology
I'm always intrigued when you make this statement, as m...
By Sheriff Fatman , 5 minutes ago
-
RE: Setback savings - fact or fiction?
Following this discussion with much interest. We oper...
By Old_Scientist , 1 hour ago
-
RE: LiFePO4 lithium battery fires and explosions
That's somewhat of an understatement. 🤨 The ...
By Transparent , 5 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@simonf thats interesting as I’ve noticed my flow and r...
By AdamK , 7 hours ago
-
RE: MELcloud scheduling misbehaviour
No, it gets to set temperature easily even during perio...
By Abernyte , 7 hours ago
-
RE: Free Ecoheat Heat Pump Install
Sorry hit 'add reply' too early, this forum layout will...
By Deltona , 8 hours ago
-
And arguably even more important, sodium will be hopefu...
By Batpred , 12 hours ago
-
RE: A Smarter Smart Controller from Homely?
I've been thinking of emailing Homely to ask for a few ...
By JohnnyB , 24 hours ago
-
Max output of Heat pump (Daikin 4Kw EDLA04)
Hello, I am a bit puzzled that according to pcdb tes...
By GeorgeA , 1 day ago
-
In that case, @technogeek, I’d sign up for the free sol...
By Majordennisbloodnok , 1 day ago
-
RE: Has Anyone Else Noticed a Decline in Tradesmanship?
@cathoderay Hence my rider about ‘all else being equal’...
By Toodles , 1 day ago
-
RE: Heat Pump Performance Analysis Web App using Modbus Data
@redzer_irl — all my heat pump data is in csv files, me...
By cathodeRay , 1 day ago
-
That’s not a problem. If you can hit the main landing p...
By Majordennisbloodnok , 1 day ago
-
RE: Configuration issues with 10kW Midea R32 heat pump
@benson I believe there are quite a few of these instal...
By Toodles , 1 day ago
-
RE: 10kw heat pump run in 24*7 data?
I would say you most likely do need 10kW. My gas consu...
By JamesPa , 1 day ago
-
RE: Mitsubishi Ecodan 11kw Defrosting Issue.
@thundermink I managed to find the fault. I did it a lo...
By meehow , 1 day ago
-
RE: Here is my heat pump installation with questionable COP in Italy
Well in Italy there is nothing controlling the quality ...
By materox345 , 1 day ago
-
RE: What a Bad Heat Pump Installation Looks Like
@editor The trick to an inside unit installation is to ...
By MikeFl , 2 days ago