Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 24, 2026
Why do buffers get such a bad press? They aren't evil, they're just not properly designed. I buffer should hold a volume of heat and absorb swings ...
@JamesPa OK, I'll give it a go (no promises), point me in the direction of what you're trying to solve. Edit: Just had a thought, one technique I u...
@cathoderay Ah OK, sounds like an interesting way to observe heat loss. I didn't mean to step on people's toes. I'm looking forward to seeing more d...
Heat transfer through objects can be determined by the equation: Q = U.A.DT Q = Energy transfered, kJ U = Heat Transfer Coefficient, kJ/m2/C A...
A slight distraction: But just to show what high temperature heat pumps can really do! Bob
Ah....yes, sorry. The spreadsheet is actually a generic calculation. My comment "the ASHP power at 12kW" was me trying to say "I've limited the inpu...
I find myself hoping for cold weather and more data 😉 Bob
Yeh...those are them 🙂 Bob
@transparent Yes, all those reasons crossed my mind when I was designing the original system. To answer your original question, please see the attac...
@cathoderay It's great your house is now getting too warm, we're making progress. It looks to me as though the average ASHP power is higher with the...
Sure, here's bunch of pictures. The plate exchanger is shoe horned into the back of the airing cupboard, it's not easy to get photos of. ...
@Transparent it's an interesting proposal. I don't think the energy balance quite works. The radiators and hot water tap remove energy from the sys...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,908 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 4 hours ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
Sooooo, what did we do in the end? We approached three ...
By Penval , 5 hours ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 10 hours ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 12 hours ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 12 hours ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 13 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 1 day ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 1 day ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 2 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 3 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 3 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 4 days ago