Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

ASHP-BOBBA
@ashp-bobba
Member Professional+
Prominent Member
Joined: Dec 6, 2024
Last seen: Oct 18, 2026
Topics: 2 / Replies: 499
Reply
RE: Samsung E911 intermittent issue

@netdonkey Ok, that looks correct to me and a nice amount of pipework above the sensor. Does the system fail on flow when heating the water as well...

2 years ago
Reply
RE: Samsung E911 intermittent issue

@netdonkey agreed, sounds ok pressure. Quick question I just thought of, can you take a picture of the flow sensor assuming the engineers fitted it ...

2 years ago
Reply
RE: New Samsung 12KW Heat Pump Help

@mike-h Oh, I am not sure I can answer accurately, When I have spoken to the manufacturers in the past they have said that ensuring the correct flow r...

2 years ago
Reply
RE: Samsung E911 intermittent issue

@netdonkey Do you feel confident to check the filter, you should be able to isolate the valve ether side and normally open a drain on the bottom of th...

2 years ago
Reply
RE: Samsung E911 intermittent issue

@netdonkey Should be shut of valves either side. the nut can be a bit tight on some of them, be sure to support the pipe when you try.

2 years ago
Reply
RE: New Samsung 12KW Heat Pump Help

@mike-h I will change my statement to: you cannot get 12kW or 10.4 or 9 Kw of heat down a 28mm pipe efficiently (this is not to say you wont get it ...

2 years ago
Reply
RE: New Samsung 12KW Heat Pump Help

@editor I would like to add further to the installers advice: I cant tell from the pipework in the picture but you will not get 12kW down a 28mm...

2 years ago
Reply
RE: Samsung E911 intermittent issue

@netdonkey The strainer can be anywhere on the rerun line from the airing cupboard / plant room to the ASHP condenser, so this could be in that room o...

2 years ago
Reply
RE: Samsung E911 intermittent issue

@netdonkey The model number for your Samsung indicates it is an 8kW system? The flow rates you are indicating only provide around 2.5kW and the code E...

2 years ago