Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

ASHP-BOBBA
@ashp-bobba
Member Professional+
Prominent Member
Joined: Dec 6, 2024
Last seen: Oct 18, 2026
Topics: 2 / Replies: 499
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

@jamespa Hi James, I never mind these questions as its helps me learn too. I see this a lot, so I think there is currently no market value for them to...

1 year ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

@jamespa Its interesting that 10% miscalculation on design and can make such a big difference to running costs compared to the boiler days. I think we...

1 year ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

@jamespa for the cheapest Its about £6500 +Vat, and £200 training, the more expensive is £11,000 and training and a loss of days works so If I get one...

1 year ago
Reply
RE: Sizing of heat pumps

@benson HI, I don't know Clivet that well but if they have the data you will be able to get it straight from the manufacturer. I though most manufactu...

1 year ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

It is expensive to gear up for either Pulse or Fan testing, some where between £10,000 and £20,000 for all the equipment and training but it would be ...

1 year ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

@matwin Quick question, do you think you would be more likely to have gone with a provider that included air testing in the building heat loss survey ...

1 year ago
Reply
RE: Radiators downstairs are cooler at the bottom after ASHP install

@melonbuffet Hi Melon, I would just concentrate on balancing as best you cvsn with clip on pipe clamps so its more accurate and then write it on a spr...

1 year ago
Reply
RE: Radiators downstairs are cooler at the bottom after ASHP install

@melonbuffet Hi, this sounds great is you are getting 5 diff on the bigger rads now, all i need you to do is the same test again with every thing full...

1 year ago
Reply
RE: Commencing on an ASHP Installation Process

@sheriff-fatman Thank you for a very detailed review of the process you went through, it is good to see that you got a wide variety of quotations and ...

1 year ago
Reply
RE: 5 Star Service from Havenwise

@hcas Excellent service, I have 2 clients about to engage your software for their systems and it is going on my new home system late this summer all c...

1 year ago
Reply
RE: Radiators downstairs are cooler at the bottom after ASHP install

@melonbuffet This is great assuming now the down stairs rads are working better? So it likely the smaller rads have a shorter DT and is closer to corr...