Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 26, 2026
@morgan that one has me scratching my head. First heard of this scheme on the Martin Lewis programme. Until late October I was off mains gas with heat...
Hi @Denevil, OK, the low rate overnight tariff is a good reason to generate HW overnight, if not the most thermally advantageous time. Defrosts are an...
Hi @Denevil, just reading this, I'm probably a month or so further on my Grant ASHP system journey, 10kW Aerona3 and 150m2 EPC C house. It's a learnin...
@marvinator80 for internal pipework, yes. for external, no. Needs to be thicker wall, minimum 19mm (3/4") and weather/water and UV resistant skin. Som...
We get very cold weeks like this 4-6 weeks of the year. When I first started researching ASHP, I realised it would be more expensive than kerosene, my...
Quite a bit of coverage over on LinkedIn about this one. And so the race to the bottom begins. Price driven installs seldom hit the required quality a...
@tim441 this is really useful info and a great find. Your experience of converting from oil to ASHP mirrors mine. I'm only 3 months into the journey h...
@derek-m Grant UK in my case. By their own admission, they 'make it easy' for tradesmen used to fitting gas boilers to fit ASHPs. But that does not ma...
Maybe a bit of wear and tear? Bleed the system of air, it's not something you want in the system. I have one TRV that quietly 'sings' when it modulate...
@abernyte "If it is the manufacturers agents then at least you know it was correctly installed and setup." - you would hope so, but... We've seen mu...
Wow! ASHPs need to deliver more flow than conventional fired boiler heating systems, as they operate a much lower delta T supply and return temperatur...
Hi @kitkad, I have a Grant Aerona 10kW installed since Oct last year. It struggled a little in the December cold snap, mainly due to the time it was s...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,590 Online
- 7,157 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@editor Thanks Mars, I have been enjoying playing with ...
By kilgorexv , 3 hours ago
-
New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
I am feeling baffled and worried:We are having a an Aro...
By GutoFfowc , 6 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 9 hours ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 9 hours ago
-
RE: Questions about A2A for heating as well as cooling
@donciccio I would suggest that you take a "fabric-fi...
By Rob of York , 10 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 1 day ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 2 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 3 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 6 days ago