Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 1, 2026
The trouble is that I do not know enough about how heatpumps work at the moment, to offer any reply to this.
Thats a lot of data!
Thank you for the info. If I am reading it right, it only quotes the output power. From the data can you work out the min input power?
Hitachi Yutaki SCombi Heat Pump(Indoor Unit ) RWD-3.0RW1E-220S-K(Outdoor Unit) RAS-3WHVRP1 2024 build bungalow200m2High level of insulationUnderfloo...
@robs On the 5. 10kW Viessmann Vitocal in Sheffield. What is causing the heat pump to turn off and on every hour (approx). It it a room thermostat o...
Thanks for your help.
I have no idea, to me there is no logic. There is no information on-line about this Hitachi system, so a bit of a loss.
The heat generated in the 5 minute period is with the pump on which goes to the manifold and floor. My de-ice cycle is exactly as yours.
In the 5 minute period the compressor is running, taking electrical power and producing heat. This, what Hitachi call a "Thermal Off" I might call a ...
The first dip is the thermal off period where the compressor stops for 3 minutes and the refrigerant in the pipe from the heat pump to the internal un...
- 27 Forums
- 2,737 Topics
- 64.3 K Posts
- 2,147 Online
- 7,143 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Grant Aerona Air to Water R290 6.5 kW - Quiet Mark and Silent Running
@bobflux Thanks for the suggestion and we’ll give it a ...
By Chris66 , 14 hours ago
-
RE: Electricity price predictions
So a final update on Charge Pack, now I have nearly rea...
By bontwoody , 18 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
My ideal install would have my battery installed before...
By BlizzardGreen , 18 hours ago
-
Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
I have a 16 year old Mitsubishi Ecodan (5kw) that has a...
By CalumM , 19 hours ago
-
RE: PV and battery long payback - sense check query
@old_scientist I have now drafted 2 replies - both have...
By DavidB , 1 day ago
-
RE: Can I start an argument about buffer tanks please? 🙂
Assume flow from the heat source is higher than flow to...
By bobflux , 2 days ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: adrian Manufacturer: Appliandirect.co....
By Adrian , 2 days ago
-
RE: Acond heat pump failed after four years - diagnostic quote £940 plus VAT
@downfield Thank you Downfield. This sounds potenti...
By Mia , 2 days ago
-
RE: Digest of UK Energy Statistics
@jeff Yes my brother in Oz told me of that charge year...
By Jancold , 3 days ago
-
RE: Love veg, hate watering cans
My dear daughter came for a bath and was given clear (I...
By Jancold , 3 days ago
-
RE: Questions about A2A for heating as well as cooling
@ashp-bobba ah that's good to know, I'll get in contact...
By donciccio , 3 days ago
-
RE: Aircon - in listed buildings
@etchedpixels thanks for giving such a full and helpful...
By GrahamF , 4 days ago