Reply
RE: The good, the bad and the not that great – my heat pump installation

The 'correct' glue to seal a split insulation like that is a contact adhesive like that from UHU. Once it's dried on each face of the split it can b...

7 months ago
Reply
RE: Battery storage solution with ASHP

The problem here is that we're trying to assess future financial viability whilst doing the maths on ToU tariffs which have been introduced recently, ...

7 months ago
Reply
RE: Air source heat pumps and noise

Interesting photo of that bracket @judith 😀 That looks to be the version of the Vaillant bracket for walls with external insulation.It use...

7 months ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

I also would NOT be temporarily re-sealing the pipe entry point after first inspecting what's been done. Instead, I'd screw a timber batten to the w...

7 months ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

IANAL but I think you removing material to inspect the way pipes pass through the wall is going to 'affect your case' either way. The installer is l...

7 months ago
Reply
RE: Battery storage solution with ASHP

@benson - I'd recommend that you check the functionality first, and the price afterwards. The GivEnergy product range is split into All-in-One ...

7 months ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

Which way is up @burtis ? Is this a close up photo of the same two pipes we saw in your earlier photo? To pass pipes through a wall there must b...

7 months ago
Reply
RE: Air source heat pumps and noise

If I was going to make my own galvanised steel clamps to hold the feet in place,then I'd start with some roofing straps. There are two gauges.The ...

7 months ago
Reply
RE: Air source heat pumps and noise

Yes. If 400-450mm is adequate for the distance between the feet positions on your ASHP, then those are fine. Most people don't bolt them down..........

7 months ago
Reply
RE: Air source heat pumps and noise

@newhouse87 - it would be difficult to use the mounting rails and shock-mounts which are already beneath your ASHP. The easier route is to buy anti-...

7 months ago
Reply
RE: Business case for a battery?

Storage battery capacity and size of inverter(s). Apart from cost, the factor most likely to dictate the battery capacity required by a home is suff...

7 months ago
Reply
RE: Business case for a battery?

Battery enclosures: The majority of storage batteries installed in UK are LiFePO4, operate at 52v nominal and have a capacity of 4-5kWh.Each box has...

7 months ago
Page 53 / 199
Share:

Join Us!

Trusted Installers

Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.

✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available

👉 Find your installer now!

Latest Posts

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security