RE: Isolating the system for a planned power cut

Apologies, I don't follow what you've written @batpred The possibility of damage from surges doesn't increase with 'high powered' devices. In fact...

4 weeks ago
Reply
RE: New Fogstar 15.5kWh upright solution

Re-read what I wrote: It has an internal oscillator. There are two ways of implementing that. 1: The output from the backup port is always at...

4 weeks ago
Reply
RE: New Fogstar 15.5kWh upright solution

That diagram is almost useless @batpred The Solis inverter itself is 'off-page' to the left,and they haven't even bothered to label the two mains co...

4 weeks ago
Reply
RE: New Fogstar 15.5kWh upright solution

I'm finding it difficult to follow your descriptions. There are two different classes of grid-tied inverter: 1: Those which synchronise to the 50H...

4 weeks ago
Reply
RE: Isolating the system for a planned power cut

That's correct. I was mentioning it as something which would be a future requirement. Both arc-detection and surge suppression devices (SPD) are l...

4 weeks ago
Reply
RE: New Fogstar 15.5kWh upright solution

Yes, there's a mass of technical assistance available from contributors to the DIY Solar Power Forum. They tend to be more technically knowledgeable...

4 weeks ago
Reply
RE: Electricity price predictions

I hear what you say about the levies which are loaded onto the electricity bills. But I still think the infrastructure upgrades are the biggest prob...

4 weeks ago
Reply
RE: New Fogstar 15.5kWh upright solution

What do you mean by "the software"? Are you referring to a piece of code which runs on a PC and just does upgrades (via a serial port perhaps)? Or...

4 weeks ago
Reply
RE: New Fogstar 15.5kWh upright solution

Have you tried going to Fogstar's website and looking for downloads? It took me about 10secs to find the instructions there! 🤔  

4 weeks ago
Reply
RE: Repiping and Reconfiguring our Heat Pump System Including Removing the Buffer Tank - Heat Pump Retrofix

Merely having air-release valves present isn't enough.They also need to be placed at the highest points in the pipework because that's where the air w...

4 weeks ago
Reply
RE: Say hello and introduce yourself

There are few heat-network schemes in UK @chris12 but I agree that they are more common in Eastern Europe. New ones are being put in when rubbish in...

4 weeks ago
Reply
RE: New Fogstar 15.5kWh upright solution

That's good news for the moment anyway. Can we try to keep your Storage Battery saga all on one topic as things progress from here? You mentioned ...

4 weeks ago