Here is some actual data we can discuss (link to data): Hypothesis: does reducing the flow rate on a DHW cycle increase the dT, allowing more time f...
I have an NRG Zone and the DHW circuit is taken off one of the "zones". This "zone" has a dedicated circulation pump which I have reduce the speed on....
Lets prove it with a fairly simple test. We do a lot of talking about this stuff in this industry, yet I do not see much empirical evidence... anywher...
I have temp sensors on the flow and return of the DHW circuit. I've reduced the pump speed from 3 to 1 for todays cycle/test (roughly 23L/min to 10L/m...
This is a very valid point, one that could be modelled out quite easily
Here you go: GitHub It works for my Riello NHXM, which should be identical to the Midea M-Thermal, Clivet Edge, Bosch CS2000AWF... Please don't ju...
First of all, let me set the scene for our "average" customer who wants a HP (South Devon): HP's still costs significantly more than a direct replac...
Great point to clarify, thank you for commenting! I'm absolutely not wanting to be associated with being 3x oversized, that is just insane. We're cu...
Hi James, firstly - thank you for contributing to this discussion, it's very much appreciated and quite enjoying the challenging of the ideas/concepts...
Yes, this is what I believe to be the case. The theory has two principles. 1. Ignoring pure weather compensation, instead run the HP in its most o...
Yep, can’t disagree with that. I must admit, I was highly motivated by performance and everything else was an afterthought.
I would like to agree with you, I really would. However, the data (my HP) shows otherwise. Oversizing is not as detrimental as people are led to belie...
- 26 Forums
- 2,406 Topics
- 54.6 K Posts
- 417 Online
- 6,092 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Rate the quality of your heat pump design and installation
🤣 what exactly did he dismiss and why?
By Mars , 13 minutes ago
-
RE: Post-Traumatic Heat Pump Stress Disorder
@jamespa Hi James - thanks so much! That sounds like ut...
By johnbroome , 27 minutes ago
-
RE: Heat pump not reaching flow temperature
@jamespa system design was for 40 degrees FT at -2 degr...
By DaveC , 46 minutes ago
-
RE: GSHP WOES! Midland based engineer recommendations?
@editor That is very kind! Thank you so much.
By johnbroome , 51 minutes ago
-
RE: Setback savings - fact or fiction?
I've now calculated the minute by minute energy flows d...
By cathodeRay , 53 minutes ago
-
RE: Considering MLCP (Multi-Layer Composite Pipe) for ASHP
@iotum, this is a really good question and you’re right...
By Mars , 55 minutes ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
That matches the TN-C-S diagram here Your post crosse...
By JamesPa , 56 minutes ago
-
RE: ASHP Energy Consumption: Aira 12kW heat pump
@wally Hi I am not sure how large your house is b...
By TechnoGeek , 2 hours ago
-
Please help with the settings ecodan
I have a 160 square meter house, first floor 6 radiator...
By nose1972 , 2 hours ago
-
RE: Predicted Heat Loss & Needs from MCS calcs vs EPC vs actual
I've been thinking along similar lines to @tim441 from ...
By Sheriff Fatman , 2 hours ago
-
Thanks, @technogeek. Good to hear about the accuracy. ...
By Majordennisbloodnok , 3 hours ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
In my case it was a very specific pattern of behaviour ...
By Sheriff Fatman , 3 hours ago
-
RE: Vaillant aroTherm not heating with many faults
@ashp-bobba Yeah I'll give it a go, will check filter...
By Anon67 , 3 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@transparent Perhaps the names at the end of the docume...
By Toodles , 3 hours ago
-
RE: Heatpunk Floor plan issues
@jamiejones85 A2A they will design on dynamic heat loss...
By ASHP-BOBBA , 4 hours ago
-
RE: Fan unit Making terrible noise HELP!!
can you post a video looking inside, at and through the...
By ASHP-BOBBA , 5 hours ago
-
RE: Power outages and storms: A surprisingly good DNO experience
Agreed, which is no more nor less than a customer shoul...
By Majordennisbloodnok , 22 hours ago
-
RE: Running from backup generaor in powercut?
@batpred In our case, 3 times each day when the Octopus...
By Toodles , 22 hours ago
-
RE: New Fogstar 15.5kWh upright solution
@batpred Here's the latest Fogstar ready built pack....
By Bash , 1 day ago