Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 14, 2024
@derek-m You just reminded me I have a pizza oven thermometer which I can use In my lounge There are 4 radiators. I took the readings from ...
@kev-m The thermometer is linked the Passiv system and you can see the temperature on the graph which is placed in the lounge. There is no other th...
@allyfish I went to the controller and these are the readings I see at the moment Circulating water return temperature - 32c Compre...
@batalto They were balanced when the additional circulating pump was installed and even then the largest radiators just weren't getting hot. Does...
@derek-m See the graph below for usage in Oct when the unit shouldn't really be defrosting given outdoor temperatures are 7c+. It's not clear to m...
@allyfish thanks for your detailed response. I don't think the unit is undersized if anything we went for something slightly bigger than what the he...
@hughf do you know anyone knowledgeable who could do this and would it invalidate any Grant warranty? I think you are right though grant just treat i...
@derek-m Thanks for your response see below for responses to your questions. Heat loss attached Yes in weather compensating mode AFAIK 21c i...
Addendum to my previous post. Also I wanted to ask if anyone else sees the sort of consumption pattern in the picture attached where the heat pump co...
- 27 Forums
- 2,738 Topics
- 64.3 K Posts
- 1,576 Online
- 7,143 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Indevolt Batteries UK Support & Info Thread
As I recall, 3kW is the maximum available from the main...
By Transparent , 9 minutes ago
-
RE: Electricity price predictions
Nationally-based Demand Flexibility makes little sense....
By Transparent , 1 hour ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Oh dear. Glad it was replaced. I have been mighty imp...
By JamesPa , 8 hours ago
-
RE: Can I start an argument about buffer tanks please? 🙂
Dont, just adjust the LSVs to get different temperature...
By JamesPa , 18 hours ago
-
RE: Heat pump running costs – what has actually worked for you?
I installed the air source heat pump in January 2026, i...
By bobflux , 21 hours ago
-
RE: Grant Aerona Air to Water R290 6.5 kW - Quiet Mark and Silent Running
Thats all interesting. DHW on my Vailant seems to respe...
By JamesPa , 1 day ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
One of the other mods has just reminded me that @ashp-b...
By Majordennisbloodnok , 1 day ago
-
RE: PV and battery long payback - sense check query
@old_scientist I have now drafted 2 replies - both have...
By DavidB , 3 days ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: adrian Manufacturer: Appliandirect.co....
By Adrian , 3 days ago
-
RE: Acond heat pump failed after four years - diagnostic quote £940 plus VAT
@downfield Thank you Downfield. This sounds potenti...
By Mia , 4 days ago
-
RE: Digest of UK Energy Statistics
@jeff Yes my brother in Oz told me of that charge year...
By Jancold , 4 days ago