Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Dec 11, 2021
All the documents can then be accessed 🙂
Scroll down the planning page - 21 School Close, Dilhorne
@batalto Planning are objecting to the calculated noise level at the neighbours - calculation done by the insatller
@editor 7m from neighbours bedroom window - but not directed at it. the bedroom window faces in a parallel direction and is set back - If I could down...
@dchilton Hi i tried to attache the PDF file of the calculations/form that the installer filled in - but no luck - the ASHP falls outside of the Permi...
@editor Staffordshire Moorlands
@kev-m The ASHP failed the MCS calcs by 7db - see the Planning Officers points, therefore the EHO says no chance - and nothing so far- my own app Sou...
@prjohn The council place all responsibility on me, my sound meter app on my phone was dismissed as not calibrated and a full sound survey was mention...
Thanks for all the replies, the following are the specific and technical points raised: Dear Mr and Mrs .... Thank you for your e-mail below r...
- 27 Forums
- 2,768 Topics
- 65.2 K Posts
- 1,932 Online
- 7,170 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Why are ASHP installs so expensive?
@batpred I take your point and, perhaps, your experienc...
By ian33a , 2 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@batpred When the raw material input has increased in c...
By Papahuhu , 22 hours ago
-
We kept ours and Heat Geek would have been in touch if ...
By Batpred , 1 day ago
-
RE: Missing flow temperature in Heat Geek proposal
The Heat geek contract had various get-out clauses with...
By Batpred , 1 day ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s I would encourage you to have a conversation ...
By Rob of York , 1 day ago
-
RE: Is it the house or the equipment?
Thanks @jamespa The last hard to fix draughts in the...
By springswood , 2 days ago
-
RE: Vaillant Arotherm – Using Heating
@l8again Mine is typically using 11w including the i...
By Batpred , 2 days ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
If you have a flowmeter and two temperature probes, the...
By bobflux , 2 days ago
-
RE: Siting of the external sensor on a heatpump
@jamespa Absolutely. Even if the same mistake was mad...
By Batpred , 2 days ago
-
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
In fairness all heating has cost a lot to run in recent...
By JamesPa , 3 days ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 4 days ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 5 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 5 days ago