Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Kev M
@kev-m
Member
Noble Member
Joined: Mar 5, 2021
Last seen: Jan 8, 2025
Topics: 10 / Replies: 1266
Reply
RE: Is my Ecodan well installed and setup?

@TRBob, I can get a csv file of data from Melcloud but I have the MMSP monitoring. I use this to do analysis and graphs in google sheets or (with a...

3 years ago
Reply
RE: Our year end review - North East Scotland

All the months except December are there? My ASHP will run constantly if it's between about 2 degrees and 9 degrees outside. Below 2 it can defrost...

3 years ago
Reply
RE: Our year end review - North East Scotland

Happy New Year to you too. Good numbers for your size of house. Our December was 970 for heating and HW for a similar sized place. When it's very ...

3 years ago
Reply
RE: Is my Ecodan well installed and setup?

That looks good to me. It's a little better than mine (my December is consumed 972 COP 3.03). The caveat is that the numbers from the FTC are estim...

3 years ago
Reply
RE: Weather compensation and air source heat pumps

Hello @abernyte and welcome. I'm very interested in your setup as it's similar to mine (I have FTC 6 but I don't think there is a lot of difference)....

3 years ago
Reply
RE: A2A as an interim ASHP measure

@ronin92 I think it's something that should be encouraged here as current A2W ASHPs don't work well heating single rooms. Not everybody wants thei...

3 years ago
Reply
RE: Air source heat pump roll call

@tommcl I didn't know the cascade system didn't give you the numbers. 105kWh at a COP of 2.5 (what I got in the cold snap) is a constant 11kW (105...

3 years ago
Reply
RE: Air source heat pump roll call

I think you might be. How much energy do you use when it's cold, i.e. as in mid-December? Have you got near your 16.5kW design power?

3 years ago
Reply
RE: New Ecodan user looking for some advice

Hi @pumpitup and welcome. It sounds like you're doing things right. Well I would say that as you're doing almost exactly what I do. Not sure what yo...

3 years ago
Reply
RE: Is my Ecodan well installed and setup?

@sunandair explained WC very well. Assuming yours is the same as mine, if you wake up the control panel and press the top right button you should ...

3 years ago
Reply
RE: What is the 'Eco' mode on hot water do?

@Tufty It heats the water up slower. I'm not sure of the details but it's something like this. Say you have your HW set to 50 deg. Normal will mak...

3 years ago