Reply
RE: Air source heat pumps and noise

This is the bracket supporting our 7kW Vaillant. It looks more substantial and is designed for an higher upper weight limit and has no noise we’ve hea...

11 months ago
Reply
RE: Valiant Aerotherm Hot Water Heating Status?

Boost goes up to your normal set temperature so it depends on how cold it has got. We can see the electricity use profile so know roughly how long it ...

11 months ago
Reply
RE: ÀSHP heat loss - how close to perfect can we get?

I totally agree that K2 are worth it. They don’t look very different to K1 or P+ and are SO much more effective. Moving to K3 is a different step in b...

11 months ago
Reply
RE: 15 year old Daikin ASHP System

I have no connection with them whatsoever but why not ask Brendon atfor advice & replacement? You’re in Cumbria and he’s well respected in the ind...

11 months ago
Reply
RE: Valiant Aerotherm Hot Water Heating Status?

If you go into system view on the app it shows flow temperature and you’ll easily see the DHW heating which ramps to become above your DHW set tempera...

11 months ago
Reply
RE: Battery storage solution with ASHP

We have a 4kW array and a Sunnyboy inverter (still working very well from original) and FIT. You need to ensure you get an AC coupled inverter into th...

11 months ago
Reply
RE: Minimum ASPH outputs?

If after reaching its minimum level continuous operation it cycles cleaning 80% on 20% off in an hour gradually reducing its on period to just ~15min...

11 months ago
Reply
RE: Moving from two zone to single (open) / how to select a circulation pump - advice please

For my part I was overwhelmed with the total number of questions. So I’ll answer a simple one: if one ufh zone is colder then yes you get it warmer ...

11 months ago
Reply
RE: ÀSHP heat loss - how close to perfect can we get?

I think a room by room heat loss is a first step but with authority/discretion to include known upgrades without full documentation (one idiot would-...

11 months ago
Reply
RE: Vaillant Aerotherm Plus - What is Green IQ setting?

If Vaillant produced a list of all of their various variables that would be valuable!

11 months ago
Reply
RE: Minimum ASPH outputs?

A snapshot of our 7kW Vaillant was at an OAT of 18C producing 1.1kW with 40% of the time on & 60% of time off. The lowest in continuous production...

11 months ago
Reply
RE: ÀSHP heat loss - how close to perfect can we get?

We get extra heat loss on wet and windy days too, even the best heat loss model, the passive house one (which does allow for solar gain and shading) d...