Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

jords
@jords
Member
Active Member
Joined: Sep 23, 2025
Last seen: Oct 27, 2025
Topics: 1 / Replies: 9
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@chas-b no unfortunately not. The most detail I received was just the loss per room.

6 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@editor I can understand why. But it’s a shame they don’t give you the details that go into the outcomes. One would assume the formulas they are using...

6 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@temperature_gradient I didn’t ask that. I assumed they were using the correct nomenclature. The surveyor told me and then I asked for clarification f...

6 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@egp01 interesting. I hadn’t heard of adia. Looks a bit like our current Tado system but for heat pumps. To be honest I thought TRVs like this were a ...

6 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@drei this is the formula i was using to rate the radiator output correct to the desired flow temp. =ROUND((((((Flow Temp + (Flow Temp - 5)) / 2) - ...

6 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@drei good to know thanks. I think there should be more than enough volume in the system. I plan for open loop other than TRVs in the bedrooms in case...

6 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@editor so my plan is to go away and upgrade all the radiators myself using the highest heat loss estimate for each room. There is about 5m of main “v...

6 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@editor Heat Geek - 8.45kW, Octopus - 10.27kW, British Gas - 7.69kW I’ll be honest I think BG have made a mistake somewhere as they wanted the most ...

6 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

@jamespa that’s an interesting way to look at it. Given my gas usage the heat loss would be around 4-5kW. But we tend to run our house on the cooler s...