Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Sep 16, 2026
Topics: 27 / Replies: 5383
Reply
RE: Help me keep the faith with my air source heat pump installation

The 7kW is (in terms of output) what most manufacturers would call an 8kW (or even 9), so this might just be a marketing exercise. However they are l...

7 months ago
Reply
RE: Midea ASHP – how to set weather compensation

You are of course correct in the short term. If the system (hp, house, rads, pipework) isn't in equilibrium something will heat up until it is, or sh...

7 months ago
Reply
RE: Midea ASHP – how to set weather compensation

Er, it does. It knows the heat loss because it knows LWT, RWT and flow rate. Thats the heat supplied which, if the house is in equilibrium, must equ...

7 months ago
Reply
RE: Any thoughts on control strategies for heat pumps?

I find it quite challenging to think about, to say the least. The simple model of a house, which we use much of the time, is a monolithic block cha...

7 months ago
Reply
RE: Rate the quality of your heat pump design and installation

That's not necessary so far as I can see. Measuring the current weather tells the heat pump or boiler whats currently happening to the outside of hou...

7 months ago
Reply
RE: Any thoughts on control strategies for heat pumps?

If you only ever want them at 18C then it would be better simply to turn down the lockshields on these rads. Then you retain the full active system v...

7 months ago
Reply
RE: Cosy 12 or Grant Aerona 15.5?

What cylinder do you currently have? There are very likely installers who wont insist on replacing it (eg Heat Geek 'Zero disrupt') BTW I used to t...

7 months ago
Reply
RE: Cosy 12 or Grant Aerona 15.5?

There is onl,y one system currently on heatpumpmonitor that is both under 200 sq m and have a measured heat demand of >9kW at the design temperatur...

7 months ago
Reply
RE: Cosy 12 or Grant Aerona 15.5?

@glacken With 3 years on this forum, I am immediately suspicious whenever I read a surveyed heat loss greater than about 9kW, unless its for a mansi...

7 months ago
Reply
RE: Any thoughts on control strategies for heat pumps?

There is essentially no doubt that operating heat pumps on well adjusted weather compensation, is, in the vast majority of cases, the way to go. In s...

7 months ago
Reply
RE: Domestic wind turbines

For a couple of years b&q sold one, but then stopped I presume because no demand. They are quite popular for narrowboats see eg/p>  

7 months ago