Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 8, 2026
Topics: 27 / Replies: 5219
Reply
RE: Oversized 10.5kW Grant Aerona Heat Pump on Microbore Pipes and Undersized Rads

Very sensible. @old_scientist has very well described the design process starting with heat loss. You seem to know your whole house loss is ~3.5kW, ...

6 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

Mostly I find Vaillant controls good, but occasionally not. The legionella cycle warning (hot water) seems to come on before the cycle runs for examp...

6 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

No it's not and i think what yhey said is nonsense (how would ut work?) Boost is, so far as i have been able to tell, a one off 'on'. However I thi...

6 months ago
Reply
RE: How to control DHW with Honeywell EvoHome on Trianco ActiveAir 5 kW ASHP

Not if you are systematic and patient. The high OAT end is logically something like 20 at 20, or more practically something like 25-27 @ 16 or there...

6 months ago
Reply
RE: Oversized 10.5kW Grant Aerona Heat Pump on Microbore Pipes and Undersized Rads

OK here goes (you did ask!)   Radiator output is dependent on the area of the radiator and the temp difference (lets call it DeltaT) between ...

6 months ago
Reply
RE: Oversized 10.5kW Grant Aerona Heat Pump on Microbore Pipes and Undersized Rads

Not that you can buy economically. You can buy temperature sensors with displays for very little, but measuring flow is invasive so more complex. &...

6 months ago
Reply
RE: Oversized 10.5kW Grant Aerona Heat Pump on Microbore Pipes and Undersized Rads

Hi, this is just a quick reply to the above quote, I will look at pictures later today.   It's not the flow rate you need to measure its the ...

6 months ago
Reply
RE: ASHP fault for DHW only with high set point – P1 error on 6kW Grant Aerona 3

Thats worrying, its like an obvious place for air to collect; why would you not put a bleed there (no need to answer that!)

6 months ago
Reply
RE: Struggling to Find a Top Heat Pump Installer? We Can Connect You With the Best Installers in the UK

In fairness my experience was 2 years ago. However the example you quote and that of @simonb seems to confirm it is still happening. The change t...

6 months ago
Reply
RE: Oversized 10.5kW Grant Aerona Heat Pump on Microbore Pipes and Undersized Rads

Firstly welcome to the forums and thank you for all the details. You are asking the right questions.   Lets start with the 10mm tails. With...

6 months ago
Reply
RE: Melcloud Home COP reports

COP of 17.7 exceeds the theoretical Carnot maximum so is definitely too good to be true. There are several periods when its producing energy but not...

6 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

Not sure exactly what your time pattern was when it didnt go how you expected but, if you still had midnight to midday programmed at 18.5 I would have...

6 months ago