Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: May 18, 2026
Topics: 24 / Replies: 4848
Reply
RE: Post-Traumatic Heat Pump Stress Disorder

@fiona @johnbroome I'm sorry to hear this. Can I just ask if you have done the key things which are necessary to get a heat pump working both che...

4 months ago
Reply
RE: Post-Traumatic Heat Pump Stress Disorder

For me this sums up what I have learned in my 3 year journey so far. Of course 'caveat emptor' is universally true - if there is an opportunity to sc...

4 months ago
Reply
RE: Heat loss based on gas usage

In a word yes.   Measurements based on a single day should be treated with extreme caution, houses take a long time to react. However as a ...

4 months ago
Reply
RE: Experience - New Build / Complete New Heating System

Newbuild 200sq m house, 16kW? Somebody is having a laugh at your considerable expense. Either the construction standard is appalling or the loss is ...

4 months ago
Reply
RE: Heat pump not reaching flow temperature

I would describe this as either a fault or a configuration error. If the ft isn't changing with oat then wc isn't working, your heat pump won't be ef...

4 months ago
Reply
RE: Post-Traumatic Heat Pump Stress Disorder

@johnbroome As I say I think you probably have a fault which needs fixing. However there may also be an opportunity to tweak how it's run. The un...

4 months ago
Reply
RE: Heat pump not reaching flow temperature

Interesting. Judging by my house which is different is several ways (some better, some worse) I would have guessed ~7kW as the actual loss, however y...

4 months ago
Reply
RE: Post-Traumatic Heat Pump Stress Disorder

OK, I see from your other post that this is quite an old installation and things have recently changed which suggests a fault. I believe @editor is l...

4 months ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

So far as i can see no because its NOT connected to the neutral, its connected to the metallic sheath of the distributor’s service cable into the prem...

4 months ago
Reply
RE: Post-Traumatic Heat Pump Stress Disorder

Sorry to heat that - it should be possible to improve on this situation. 'The rest of the house cold' suggests you are not heating the whole house,...

4 months ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

That matches the TN-C-S diagram here Your post crossed with mine which has both diagrams from the IET and a bit of a comment.

4 months ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

Please dont feel obliged to respond quickly or at all, we all do this in our time on an as and when basis. I am very grateful for any input which has...