Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Sep 16, 2026
Topics: 27 / Replies: 5383
Reply
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!

Balancing can be a long process (it can also be very quick especially if the settings are almost right) and its possible to mess things up if you turn...

6 months ago
Reply
RE: Daikin Altherma 3 LT compressor longevity question

Up to a point yes. However every heat pump (and every boiler) can only turn down so far, ie it has a minimum output (which, in the case of a heat pum...

6 months ago
Reply
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!

By opening up the lockshield valve on the radiator in question, or closing down a bit lockshield valves on other radiators (the lockshield valve, ofte...

6 months ago
Reply
RE: New Build ASHP Defects - Looking for Advice, Support & Shared Experiences

Is that a single pair only? If so it may be part if the problem. How long? What flow rate do you have ( your heat pump will tell you) and what dt f...

6 months ago
Reply
RE: New Build ASHP Defects - Looking for Advice, Support & Shared Experiences

Should be interesting. Do watch to see if the UFH gets too hot, although if it does then thats a positive outcome!  

6 months ago
Reply
RE: If a heat pump can only heat DHW to 50C then what? Issue with 18KW Heliotherm heat pump

Sorry to hear that but I'm not surprised TBH. Stratification is effective in a normal unvented tank where the hot water is drawn off at the top. In ...

6 months ago
Reply
RE: Refrigerant R32, is it now banned in the EU from 1st Jan 2027 for monobloc ASHPs?

I wonder if heat pump manufacturers will tone these siting restrictions down. I suspect so. They aren't, so far as I have been able to establish, ac...

6 months ago
Reply
RE: Advice needed after a successful "leftfield" experiment.....

Re (2) I misinterpreted your earlier post. The actual requirement is here "(ii)the system providing space heating or water heating, or both, of ...

6 months ago
Reply
RE: New Build ASHP Defects - Looking for Advice, Support & Shared Experiences

@newby OK here are my considered thoughts based on info so far: Very sensible!   General comments:   I think its unlikely, bu...

6 months ago
Reply
RE: Rate the quality of your heat pump design and installation

Loss assessments can be a very serious case of GIGO. I had two, both coming out at 16kW following, in each case, a 3 hour survey. I did the calculat...

6 months ago
Reply
RE: Advice needed after a successful "leftfield" experiment.....

You will struggle to persuade an installer to do this and nor would I necessarily advise it without careful thought (although I wouldn't rule it out e...

6 months ago