Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 27, 2025
good luck convincing anyone that their radiators will never be warm to the touch... That's why I stick with 38.5 as the hot end of my WC curve - it's ...
@toodles It is purely there to allow the heat pump to operate without any flow errors... Primary side just sits there running into the header, microbo...
@bontwoody indeed, although I would question the viability of having radiators that don't feel warm to the touch, from a homeowner acceptance perspect...
It is my suspicion too, that in milder weather, we are simply oversized. I didn't take into consideration the possibility that the ACH value used in t...
@heacol SCOP only needs to be 2.8 to beat gas - and that's what it's all about... not costing more than a gas boiler.
@jamespa flow temp.... get that accurate first, then tweak the WC curve up/down as required. Think I've got the curve vaguely correct at the moment, s...
@derek-m single heat pump, just run on weather comp, no stats, no setback. The Carel platform that my heat pump is built on allows full tuning of th...
@jamespa I’ve spent ages tweaking the P, I, and D on mine to try and get a decent response without overshoot. It’s not easy, especially when 1. We’re ...
On the subject of control strategy, some units can be set to control on LWT or RWT…. Mine used to be switchable between the two but a recent softwa...
GH has been involved in heat pump installs since the early days, he knows his stuff. He also had to come up with workarounds for flow rate issues that...
I’m sorry I can’t provide anything helpful, but I’m mighty glad I didn’t need a header or buffer in my install. It seems like a nightmare.
@bontwoody scop of 3.2 is certainly achievable, but not very easily on a retrofit unless you design for 45 degree flow, maximum. With octopus (for exa...
- 27 Forums
- 2,783 Topics
- 65.6 K Posts
- 2,144 Online
- 7,187 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
I'd be surprised if it wasn't a noise consideration. Ne...
By Majordennisbloodnok , 25 minutes ago
-
RE: Indevolt Batteries UK Support & Info Thread
I've got a podcast recording scheduled this week where ...
By Mars , 13 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
I’m a little late posting this, but it’s genuinely one ...
By Mars , 13 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Ah, that makes sense when a combi is in place. The boil...
By Batpred , 15 hours ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
@bobflux Thanks, that gives me something to check the i...
By Paul1098 , 16 hours ago
-
RE: Tesla Powerwall (2) Calibration Cycles
For Powerwall calibration, avoid forcing repeated deep ...
By EnergyStorageTech , 1 day ago
-
Over the years, due to the non barrier PEX underfloor h...
By bobflux , 1 day ago
-
RE: Getting closer to a finished Haier system
All the 45° elbows required for getting the primaries i...
By Singlespeed , 2 days ago
-
RE: battery storage without solar
Indeed, current on the grid input = current used for ch...
By bobflux , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu @papahuhu A lot of tears and sweat went into ...
By Andris , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
We have the same problem, 12 mature trees clip the morn...
By Papahuhu , 4 days ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
I had a battery and inverter installed a while ago, my ...
By Batpred , 4 days ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@ltron2 The EPC on our house is A-92, however that i...
By Rob of York , 4 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
The layout is confusing - much better like this: We b...
By downfield , 5 days ago
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
My experience, backed up by opinions from various frien...
By Majordennisbloodnok , 5 days ago