Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 27, 2025
good luck convincing anyone that their radiators will never be warm to the touch... That's why I stick with 38.5 as the hot end of my WC curve - it's ...
@toodles It is purely there to allow the heat pump to operate without any flow errors... Primary side just sits there running into the header, microbo...
@bontwoody indeed, although I would question the viability of having radiators that don't feel warm to the touch, from a homeowner acceptance perspect...
It is my suspicion too, that in milder weather, we are simply oversized. I didn't take into consideration the possibility that the ACH value used in t...
@heacol SCOP only needs to be 2.8 to beat gas - and that's what it's all about... not costing more than a gas boiler.
@jamespa flow temp.... get that accurate first, then tweak the WC curve up/down as required. Think I've got the curve vaguely correct at the moment, s...
@derek-m single heat pump, just run on weather comp, no stats, no setback. The Carel platform that my heat pump is built on allows full tuning of th...
@jamespa I’ve spent ages tweaking the P, I, and D on mine to try and get a decent response without overshoot. It’s not easy, especially when 1. We’re ...
On the subject of control strategy, some units can be set to control on LWT or RWT…. Mine used to be switchable between the two but a recent softwa...
GH has been involved in heat pump installs since the early days, he knows his stuff. He also had to come up with workarounds for flow rate issues that...
I’m sorry I can’t provide anything helpful, but I’m mighty glad I didn’t need a header or buffer in my install. It seems like a nightmare.
@bontwoody scop of 3.2 is certainly achievable, but not very easily on a retrofit unless you design for 45 degree flow, maximum. With octopus (for exa...
- 27 Forums
- 2,767 Topics
- 65.1 K Posts
- 983 Online
- 7,169 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Next steps on my ASHP journey: Radiators and Pipework
If you are considering phasing the project, then I woul...
By GrahamF , 4 hours ago
-
RE: Siting of the external sensor on a heatpump
Of course had the heat source been a heat pump it would...
By JamesPa , 6 hours ago
-
Never assume, it makes an ass of u and me! OK, tha...
By JamesPa , 6 hours ago
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
In fairness all heating has cost a lot to run in recent...
By JamesPa , 8 hours ago
-
RE: Is it the house or the equipment?
@springswood We have two Daikin single split A2A syst...
By Rob of York , 9 hours ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 1 day ago
-
No, but the heat pump must be capable of delivering a S...
By JamesPa , 2 days ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 2 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 2 days ago
-
RE: Vaillant Arotherm Plus 7KW need a service on it
booked it with Vaillant. will use them until i can find...
By AdamK , 2 days ago
-
RE: Adventures in heat loss calculations
I have seen it stated that the declared calorific value...
By JamesPa , 3 days ago
-
RE: Two heating zones to one zone
@transparent Many thanks. The garage is fairly well ...
By Profzarkov , 3 days ago
-
RE: Vaillant Aurotherm - Heater Wire Position
Ah, good point. I need to check if this was installed i...
By Batpred , 4 days ago
-
@batpred thanks for getting a copy. Appreciate the supp...
By Mars , 4 days ago
Members Online
No online members at the moment