Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 27, 2025
Who did your install? If it was supplied through freedom then they would have followed the manual written at freedom, and that specifically uses fixed...
If you wired it up with a pwm primary pump and used the samsung controller directly, I'd expect you'd see that COP up between 4 and 5 in the current w...
@cathoderay I've modified Freedoms calculator (tweaked the w/m2 value) to size my rads for a 45 degree flow temp and I'm shooting for 35% oversize in ...
@cathoderay Similar to our install, 1946 block/block construction with a 2" cavity, that has been blown. Double glazing, suspended timber floors an...
Attached is the samsung gen6 manual as supplied by midsummer wholesale. Their installation instruction and wiring is more advanced than that from Joul...
I doubt you'd get a meaningful answer from the installers.
Samsung mono controller manual attached, this clearly shows the connection for external PWM pump control, Connection 10 on the main PCB. It even say...
Whether it will make a whole lot of difference to your COP remains to be seen, but usually, with a modulating compressor (all modern ASHPs are inverte...
From looking at two samsung installation manuals, one from Joule (that because of an ssl certificate issue, I couldn't download) and one from Secon re...
It's not a pump that's controllable by the ASHP so it's not something to mess with. The manual for that pump is attached for your information.
All decent, modern ASHPs have speed and hence flow rate control of their pumps (except it would appear, Samsung): This article by Graham Hendra cov...
You should use the TRVs in the upstairs rads to limit the temperature in those rooms, yes. You should remove the actuator heads from the downstairs TR...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 288 Online
- 7,157 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@editor Thanks Mars, I have been enjoying playing with ...
By kilgorexv , 3 hours ago
-
New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
I am feeling baffled and worried:We are having a an Aro...
By GutoFfowc , 5 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 8 hours ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 8 hours ago
-
RE: Questions about A2A for heating as well as cooling
@donciccio I would suggest that you take a "fabric-fi...
By Rob of York , 9 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 1 day ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 2 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 3 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 6 days ago