Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 27, 2025
Who did your install? If it was supplied through freedom then they would have followed the manual written at freedom, and that specifically uses fixed...
If you wired it up with a pwm primary pump and used the samsung controller directly, I'd expect you'd see that COP up between 4 and 5 in the current w...
@cathoderay I've modified Freedoms calculator (tweaked the w/m2 value) to size my rads for a 45 degree flow temp and I'm shooting for 35% oversize in ...
@cathoderay Similar to our install, 1946 block/block construction with a 2" cavity, that has been blown. Double glazing, suspended timber floors an...
Attached is the samsung gen6 manual as supplied by midsummer wholesale. Their installation instruction and wiring is more advanced than that from Joul...
I doubt you'd get a meaningful answer from the installers.
Samsung mono controller manual attached, this clearly shows the connection for external PWM pump control, Connection 10 on the main PCB. It even say...
Whether it will make a whole lot of difference to your COP remains to be seen, but usually, with a modulating compressor (all modern ASHPs are inverte...
From looking at two samsung installation manuals, one from Joule (that because of an ssl certificate issue, I couldn't download) and one from Secon re...
It's not a pump that's controllable by the ASHP so it's not something to mess with. The manual for that pump is attached for your information.
All decent, modern ASHPs have speed and hence flow rate control of their pumps (except it would appear, Samsung): This article by Graham Hendra cov...
You should use the TRVs in the upstairs rads to limit the temperature in those rooms, yes. You should remove the actuator heads from the downstairs TR...
- 26 Forums
- 2,610 Topics
- 60.8 K Posts
- 1,336 Online
- 6,967 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Electricity price predictions
Bear in mind that my maximum daily draw over winter was...
By KevH , 49 minutes ago
-
RE: Seeking ideas / information / commiseration - Pure Drive
That may well be correct. However we don't have enoug...
By Transparent , 2 hours ago
-
@cathoderay up until the last few days the rads have al...
By Painter26 , 3 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
That's puzzling me too. Along similar lines ( forgive...
By colinc , 5 hours ago
-
RE: Rate the quality of your heat pump design and installation
@editor Thank you. I joined because I really liked your...
By claireisamazing , 19 hours ago
-
I cant, but @editor probably can if you tell him roughl...
By JamesPa , 20 hours ago
-
RE: UK DIY Battery: SEPLOS 48V 200Ah x2 + Sunsynk 8K – Safe Installation for Garage Conversion
@madsid I don't quite understand what extra you need...
By Bash , 22 hours ago
-
@transparent thank you. Be Thursday before my mate giv...
By David999 , 24 hours ago
-
RE: Peak Energy Products V therm 16kW unit heat pump not reaching flow temperature
@johnd our Peak system is no more. The installer cam...
By DaveC , 24 hours ago
-
Hah! Well I guess we're all in the realm of conjectu...
By Transparent , 1 day ago
-
These are a bit hard to read but the information is in ...
By bobflux , 1 day ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
Ah, not so useful then For sure, hopefully before ...
By JamesPa , 1 day ago
-
Thanks @editor I appreciate that things go wrong, bu...
By venkman , 1 day ago
-
RE: Home energy storage & battery register
AC coupled Pure Drive 10kW battery Solar PV Solis P...
By Little Lights , 2 days ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: ispookie666 Manufacturer: Vaillant Mo...
By ispookie666 , 2 days ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
I'm fairly new to the forum and have not voted. Back...
By ispookie666 , 2 days ago
-
I am seeing an increasing number of occasions when my G...
By DavidAlgarve , 2 days ago
-
RE: End-of-Life Heat Pumps: How Do You Dispose of an ASHP in the UK?
@editor Thanks Mars. I look forward to the subsequent ...
By DavidB , 2 days ago
-
RE: Anyone concerned about GivEnergy?
Fair enough. Its interesting that opentherm (for boil...
By JamesPa , 2 days ago
-
RE: Brand and installer questions for ASHP
A tank solely in the return (upstream of where the retu...
By JamesPa , 2 days ago
-
RE: Home automation and the cloud; is there a better way?
+1 It's not just cloud though. Many devices have repla...
By bobflux , 3 days ago
-
RE: Summer usage. Why is my Vaillant Aerotherm using so much energy on "heating"?
So the red bars are 'DHW' and the yellow bars 'heating'...
By JamesPa , 3 days ago
-
RE: Renewables & Heat Pumps in the News
Critics and naysayers will be negative whatever the gov...
By JamesPa , 3 days ago
-
RE: Microbore heat pump installs
In principle you are almost certainly right, but in pra...
By JamesPa , 4 days ago