Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 1, 2025
@robs The flow rate is determined by the capacity of the unit. If you close a valve in the flow, the pump speeds up to try to match the desired fixed ...
@heatgeek 👍
@heatgeek No offense taken or inferred. The problem is, no-one actually knows but many claim to, and are disseminating unverified information as fact....
@heatgeek You state "Beware disinformation on this forum", then you state "The theoretical power level was calculated " and finally "Vaillant Arotherm...
@jamespa There is no consensus as manufacturers will not supply their test data, however, it is very much based on the design of the refrigerant circu...
@jamespa, please do not make assumptions when you admit that you do not understand the topic. There are reasons for the 5 Deg Delta T but they are exc...
@sunandair a red herring, cycling is not the problen some make it out to be.
@sunandair That is what I would expect from a system with adiquate volume. The panasonic prevents the flow temperature dropping below 25 Deg C which i...
@sunandair You are correct, the volumisor on the flow will buffer the cold shock comming from the heat pump going to the radiators and the asociated d...
@robl Your analysis is correct, for heating the most efficient Delta T across the condensor is in fact 5 Deg C and most manufacturers will reccomend t...
@jamespa Install one of these on the main incommer.
@adamk Yes you can to that. I never use old radiators. If the customer insiste, I walk away, it is not worth it.
- 26 Forums
- 2,631 Topics
- 61.5 K Posts
- 941 Online
- 7,027 Members
Join Us!
Latest Posts
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
One more quick one. A local installer I contacted has j...
By springswood , 24 minutes ago
-
RE: Estimating true heat loss from twelve months of consumption data
Hi @ian33a you could do your own heat loss calculation ...
By Judith , 8 hours ago
-
RE: Anyone concerned about GivEnergy?
@sunnyskies I agree with Downfield trying to ask the GE...
By Judith , 9 hours ago
-
RE: Setback savings - fact or fiction?
@jamespa — this version may be marginally better: &nb...
By cathodeRay , 10 hours ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
All going according to plan, mid July we get that 7kW a...
By Batpred , 11 hours ago
-
Current metrics - DHW target set to 47c
By TaffontheTaff , 16 hours ago
-
RE: My Grant R290 9kW Heat Pump Installation
@petch I'm very sorry that I have not picked up your po...
By GrahamF , 18 hours ago
-
RE: Samsung gen 7 HP 12kw - auto control issue and water law
Suggest you have a trial with Havenwise app. I have th...
By Broadsman , 20 hours ago
-
RE: New Solar, Batteries, Air Source and Under Floor Heating advice please
You’re right: UFH works best with high-conductivity fin...
By bafab , 23 hours ago
-
RE: DIY or Don’t Touch? Solarman Smart Meter Install
That was my understanding also.
By JamesPa , 23 hours ago
-
RE: Grant Aeona 3 R32 cycling with weather compensation.
That would be abnormal but I cant see from your charts ...
By JamesPa , 23 hours ago
-
RE: Vaillant Sensocomfort Time
Oh I remember this from when I set mine up 2 years ago,...
By JamesPa , 1 day ago
-
Heat geek have already stated that the pro is in fact c...
By JamesPa , 1 day ago
-
RE: The Myth of the MCS Performance Guarantee
@editor I know. As if MCS wasn't bad enough, it's now e...
By Deltona , 1 day ago