Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 1, 2025
@kev-m Sorry My mistake re The COP, I missred the graph. đŸ˜– That sounds great, I think you will find a huge diffreance. @morgan, 25 - 45 is 2...
No, it is still like driving a car in to a 100 mile an hour head wind. This is what they look like inside and this is how they work, the water ...
@kev-m Thanks Kev, I will try to be gentle!! đŸ˜€ You have just given me all the evidence I need to prove that you are running your system incorrectly....
@markc You only need 1 valve to divert the water from heating to hot water. I have left the one in your anex as you may not use it all the time and wi...
@batalto Nice indication of the implacations of flow temperature, try to drop your curve even further and disable all you other levels of control by t...
@markc do not expect to improve your COP very much, if you do not do anything. By the way, you only need 1 valve and about 3 hours of a good plumbers ...
@markc So changing the synchron valves for diverter valves makes the change that the hot water flow is no longer stopped, but allowed to keep flowin...
@markc Your system is very cloce to what it should be. Here are the alteratins that need to be done, chiange your control to full weather compensation...
@editor Looks an interesting system. From to pictures it appears that you have 3 pumps running in addition to your pumps in the heat pump and boiler. ...
@editor Yes, yours is a combined unit, Hot water cylinder at the top and buffer on the bottom. A good cylinder, I use them sometimes if the system i...
@editor Mars, can you give me a picture of the pumps and valves ect cut from your picture.
@editor Yes it is possable, ther are some combined units on the market.
- 26 Forums
- 2,714 Topics
- 63.6 K Posts
- 309 Online
- 7,114 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
-
RE: Mitsubishi Ecodan FTC6 settings
While @F1p's dongles are great, the FTC can do this its...
By RobS , 4 hours ago
-
RE: Samsung heat pump - data cable issue
If it's a data cable, current will be minuscule, voltag...
By bobflux , 5 hours ago
-
RE: Rate the quality of your heat pump design and installation
I'm kind of at the end of my heat pump installation now...
By JandP , 9 hours ago
-
RE: MCS Quality Audit – Has Anyone Had One? Did It Lead to Remediation?
I got hit with an RHI audit in 2022. It was far from c...
By Abernyte , 10 hours ago
-
RE: Electricity price predictions
@papahuhu Groucho Marx had something to say about no...
By Toodles , 12 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@jamespa haha very true, although the engineer yesterda...
By swwils , 18 hours ago
-
RE: Vaillant Arotherm Pro vs new Plus
One of the test modes in the installer menu forces it t...
By JamesPa , 1 day ago
-
RE: What a difference a few degrees make.
Wow. Having accepted the challenge, I ran the cold tap ...
By Old_Scientist , 1 day ago
-
RE: HeatPump maintenance in Swindon area?
@vince31 have you tried using our finder:/p>
By Mars , 1 day ago
-
Looking for beta testers for a new homeowner heat pump tool
Over the past few months I've been building a brand new...
By Mars , 1 day ago
-
-
RE: Indevolt Batteries UK Support & Info Thread
It depends on how you configure it via the app. The ma...
By JamesPa , 1 day ago
-
RE: Renewables & Heat Pumps in the News
Be interesting if this results in any wider changes to ...
By Jeff , 2 days ago