Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 1, 2025
No unit should be using it's immersion element at this ambient temperature. It is only permitted to come on after the design duty point, which should ...
@marzipan71 You may befit from replacing the valve, it will depend on the current flow rate and system design. If you have a buffer tank, it will prob...
The ground loop pump must run when the heating is on, it may be a connection problem or the board has failed. You can as a temporary measure try conne...
It is quite possible to install a high temperature heat pump, and you can run it at high temperatures if you want to double your heating bill. However...
@derek-m Correct but the best way to control flow is automatically with equipment that can do it for you. If your system does not have Delta T contro...
@soniks Firstly, the engineers at Grant need to buy a new calculator or go back to school. 50 L/min will transmit 28Kw. You only need to transmit abou...
@soniks As I said, 28 mm will be fine, a 28 mm pipe has an internal diameter of 26.2 mm, the Grant 17 Kw will produce about 14 Kw at -2 at 50 odd degr...
@soniks change 28 mm primaries--- wrong, I have 30Kw heat pumps on 28 mm primaries very successfully Buffer tank--- Wrong in any circumstance unless...
@kev-m I understand where you are coming from, but it is wishful thinking. The industry did try to do exactly what you are asking and came up with the...
@derek-m Oh I wish. Unfortunately, we follow behind a myriad of idiots that blow your assumptions out the water.
@kev-m Unfortunately you are Oh- So-Wrong. If the builders had followed the building regulations over the last 30 years, you may be right, but they ha...
- 26 Forums
- 2,658 Topics
- 62.2 K Posts
- 353 Online
- 7,060 Members
Join Us!
Directory
Latest Posts
-
RE: Rate the quality of your heat pump design and installation
@trebor12345 Good to hear of another satisfied Cinergi ...
By Toodles , 18 minutes ago
-
RE: Indevolt Batteries UK Support & Info Thread
@transparent yes I understand. The indevolt wouldn't kn...
By iRadiate , 27 minutes ago
-
RE: Cooling with air to water heat pumps
On the two huge (10m² each) south facing windows I inst...
By bobflux , 2 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent I don't think Axle have any involvement...
By Tim441 , 2 hours ago
-
I'm the general case no (at least not yet). But if ins...
By JamesPa , 4 hours ago
-
RE: Failed Heat Pump Install: IWA Claim Rejected
Many of the estimates we received mention IWA and RECC....
By Batpred , 1 day ago
-
RE: Rural burning – I've had enough
Same here in Finland. It's strictly forbidden ...
By upnorthandpersonal , 1 day ago
-
RE: Renewables & Heat Pumps in the News
Something worth flagging... we've just published a news...
By Mars , 1 day ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
The Homeowners' Q&A podcast is back... I've changed...
By Mars , 1 day ago
-
RE: Anyone concerned about GivEnergy?
I have already signed up with Axle so yes, that takes c...
By KevH , 1 day ago
-
@batpred Would it pass the airbnb feedback test no. I...
By EtchedPixels , 2 days ago
-
A quick update... we've just launched the beta version ...
By Mars , 2 days ago
-
RE: Who Actually Owns a Heat Pump in Britain? We Asked. Here Is What We Found.
The age part doesn't surprise me - only 25% of UK home ...
By EtchedPixels , 2 days ago