Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 1, 2025
No unit should be using it's immersion element at this ambient temperature. It is only permitted to come on after the design duty point, which should ...
@marzipan71 You may befit from replacing the valve, it will depend on the current flow rate and system design. If you have a buffer tank, it will prob...
The ground loop pump must run when the heating is on, it may be a connection problem or the board has failed. You can as a temporary measure try conne...
It is quite possible to install a high temperature heat pump, and you can run it at high temperatures if you want to double your heating bill. However...
@derek-m Correct but the best way to control flow is automatically with equipment that can do it for you. If your system does not have Delta T contro...
@soniks Firstly, the engineers at Grant need to buy a new calculator or go back to school. 50 L/min will transmit 28Kw. You only need to transmit abou...
@soniks As I said, 28 mm will be fine, a 28 mm pipe has an internal diameter of 26.2 mm, the Grant 17 Kw will produce about 14 Kw at -2 at 50 odd degr...
@soniks change 28 mm primaries--- wrong, I have 30Kw heat pumps on 28 mm primaries very successfully Buffer tank--- Wrong in any circumstance unless...
@kev-m I understand where you are coming from, but it is wishful thinking. The industry did try to do exactly what you are asking and came up with the...
@derek-m Oh I wish. Unfortunately, we follow behind a myriad of idiots that blow your assumptions out the water.
@kev-m Unfortunately you are Oh- So-Wrong. If the builders had followed the building regulations over the last 30 years, you may be right, but they ha...
- 27 Forums
- 2,748 Topics
- 64.7 K Posts
- 2,581 Online
- 7,155 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 3 hours ago
-
@kilgorexv, I actually think doing your own calculation...
By Mars , 3 hours ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 17 hours ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 1 day ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 2 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 2 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
There is scope for product development here. I for one...
By JamesPa , 2 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 2 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 5 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
First time poster here but I can share my experience as...
By SCH , 5 days ago
-
RE: Is it the house or the equipment?
...which, I've found out, is pretty much impossible to ...
By Majordennisbloodnok , 6 days ago