Mine appears(?) to be fixed flow. There are two pumps in my system, as I understand things, one pumping on the return side into the HP, the other on t...
I'm going to ask a potentially really dumb question, but it's one I've been wanting to ask. What does the (1-5) pump speed setting in the FTC contro...
Wow, this exposes a whole bunch of information. At a quick glance I'm not sure if there is anything listed that's not already exposed via the Melcloud...
lol. Assuming I've not missed anything, I do wish they would standardise the naming. I'm guessing they re-branded it at some point.
I just want to check I'm not miss-understanding something. I thought Room Temp Mode, and Auto-Adaptive Mode were the same thing, the two names just ge...
Yes, no cycling when doing DHW. Here's a chart of a typical DHW re-heat.
Yeah, 43 + 5 (default thermo diff upper limit value) does not = 53. I'm equally confused why it's chosen that initial value - did it not settle at low...
You suggested it as something to try to see if it had any positive improvement on the cycling at mild ambient temps I've been observing. I do have the...
lol. And I did allude to that earlier - if those settings only apply in AA mode, why oh why don't/can't they apply in other modes (are Mitsubishi tryi...
I tried 60 mins for a couple of day's in AA mode - no change that I could see.
In terms of the thermo diff adjust, it does appear to do what it says on the tin from my testing, I've not seen it go way over or under the Upper/Lowe...
It had me confused at first. But in the FTC6 manual it quite clearly states all those settings are for room temp mode only. Also in all my tests it's ...
- 26 Forums
- 2,289 Topics
- 51.4 K Posts
- 278 Online
- 5,949 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
we are talking the same thing. Its crazy if its really...
By JamesPa , 46 minutes ago
-
RE: Electricity price predictions
I agree, the operation of a system managing hundreds of...
By Batpred , 46 minutes ago
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
@jamespa Yes, the OAT sensor is situated on the back pa...
By Toodles , 46 minutes ago
-
RE: DHW heat loss through pumps.
Ah, you have a water circulation loop, (like in hotels)...
By JamesPa , 52 minutes ago
-
RE: Ecodan ASHP Low COP and Unstable Compressor Frequency
Just to clarify, returning water from UFH is colder tha...
By lukewarmbath , 1 hour ago
-
RE: 10kw heat pump run in 24*7 data?
A different heat pump (Midea 14kW) but a stark reminder...
By cathodeRay , 1 hour ago
-
From what I see, the work to upgrade the cable, etc all...
By Batpred , 2 hours ago
-
RE: Confusion over Octopus Tariffs
That's sounds great. I have no ASHP, but 15kwh storage....
By Batpred , 2 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
Locked environments are difficult to manage, it also me...
By Batpred , 2 hours ago
-
RE: Do Heat Pumps need to start up at Full Power?
@steelbadger Attached is the plot for various parameter...
By Toodles , 6 hours ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Hi all, I had a 15kw installed 3 weeks ago. The past we...
By jamesh , 7 hours ago
-
Adia Therma - 'autopilot for heat pumps'
Thought I'd pop this one in here as the Adia proposal a...
By seatonian , 21 hours ago
-
RE: Mitsubishi Ecodan R290 10kW performance
Don't know answer to final question. Your contract p...
By JamesPa , 21 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Ah, it seems PACE BMS are easy to source on AliExpress,...
By Batpred , 22 hours ago
-
RE: Vaillant water pressure gauge vs Analogue gauge
@jamespa Agreed I don't feel concerned about this, espe...
By jeegnesh , 23 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
@toodles Yep, and it is not even a sticking plaster ...
By Jeff , 1 day ago
-
RE: Renewables & Heat Pumps in the News
I agree, imperfect systems like voting for politicians ...
By Batpred , 1 day ago
-
RE: Gov wants to alter our FIT contracts from rpi to cpi
The consultation is just part of the normal process for...
By Jeff , 1 day ago
-
@transparent @old_scientist Quick update, I submitted...
By Batpred , 2 days ago