Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 13, 2025
The Ecodan WC curve doesn’t have presets like you see in other systems it’s fully customisable. So you can set the high and low end at any OAT and ch...
My heat pump by luck is sized correctly and defrosts hourly. All you can do is keep the flow temp to the minimum you need and keep it running so you ...
I have an 8.5kw heat pump and its currently running at 36C and pulling 2kw so not miles away from yours, when it runs at 45C its will pull 3.5kw, ther...
@boycey If you are running at 26C and the house is 20C then your UFH isn't going to be able to get rid of any heat as the room temp is too close to th...
if you click on tank temp and set temp in the legend it will remove them from the plot it will rescale you will then be able to see what the flow tem...
That will just prevent the heat pump from setting a temperature lower than 30C, its easier just to adjust your weather compensation curve. Can you po...
Just to add my 2p, I have an Ecodan and UFH, to avoid cycling on and off then we need set the flow temp at a minimum of 32C, from your plots it looks ...
As you state L9 is flow rate error, if you go to the service menu when the heat pump is running and then go into running information and put in code 5...
between 3 and 8 depending on flow temp, Ecodan so fixed flow rate.
@athlonoc you don't have a mitsubishi preplumbed cylinder so the FTC probably can't control the pump speed but that is easy to check on the FTC go to ...
@athlonoc You don't need 24L/min for an 8.5kw heat pump, Mitsubishi's own manual states 15.2L/min, 24L is the absolute maximum so i'm not surprised it...
- 27 Forums
- 2,816 Topics
- 66.7 K Posts
- 3,672 Online
- 7,230 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Should I change my cylinder when changing from a gas boiler to a heat pump.
I did the Heat Geek Mastery course a while ago and cyli...
By Mars , 12 minutes ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
The Heat Geek survey and design process continues to ge...
By L8Again , 25 minutes ago
-
RE: Plug and play solar. Thoughts?
Impressions so far from the one I've installed are that...
By EtchedPixels , 10 hours ago
-
-
@batpred The Daikin temperature probe protrudes from th...
By Toodles , 14 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
@editor And as an occasional contributor, may I say wel...
By Toodles , 16 hours ago
-
RE: Should Households Who Can Afford It Pay More for Energy to Help Those Who Can't?
They don't have to try. Our entire system is d...
By EtchedPixels , 16 hours ago
-
RE: Why don't people choose heat pumps?
Fair enough. I guess I was thinking of pipes that run ...
By JamesPa , 16 hours ago
-
RE: How Can I Prove Coal Was My Main Heating Source Without Receipts?
Got excepted for the grant now so thanks for the replie...
By Chilli304 , 20 hours ago
-
Daikin Altherma 3 R F+W, room thermostat control, weath...
By JanHarley , 21 hours ago
-
RE: Buffer tank on a 2 x 14kw Ecodan system
Pretty much as I had guessed in my crude scaling from m...
By JamesPa , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
Well you have a vibration generator running at some fre...
By bobflux , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@downfield Thats a decent rate, I’m shocked they hadn...
By Papahuhu , 2 days ago
-
RE: Adventures in heat loss calculations
@toodles thanks! So as suspected, around a doubling of ...
By SusannaSaunders , 3 days ago