The interesting words are in the last sentence as detailed below. The low loss header is just one way, but hopefully it provides engineers with an i...
I would suggest that you check that the valve or valves are changing over from central heating to DHW heating. Edit. I suppose that the other thin...
It is the Compressor which moves the refrigerant gas around the system. I have seen a number of engineering drawings showing a water pump located insi...
I think that this could be a training video, with the heat pump set up indoors, not too far from the controller. One way to check if the outdoor uni...
Without knowing where CT2 is connected I'm afraid that I cannot say. I would suggest that yo contact your installer.
It suspect that it means that Current Transformer number 2 (CT2) is installed the wrong way around. Is it a newly installed system?
What happens if you run room temp mode with the Auto Adapt dip switch 5-2 set to inactive? I haven't tried it nor do I know if it's even possible. ...
In the first place the pump should not have been mounted with the motor and electronics below the water filled pump section, unless the water in your ...
It's just good business. Confuse the customer with 'smoke and mirrors', so they have to pay for a visit from the expensive Service Engineer. Simples. ...
which also made me wonder if my system is configured from Room Temp or AA. I don't know if there is anyway of telling? [/quote] Room Temperatu...
You little devil, you've been reading the instructions again. Shame on you. 😋
You will not get cycling in DHW mode because the heat pump is working harder, so is operating within its specified control envelope. Cycling occurs wh...
- 26 Forums
- 2,158 Topics
- 47.4 K Posts
- 50 Online
- 5,736 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
@njt That sounds a good deal and at least he appeared t...
By dgclimatecontrol , 18 minutes ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
While I won't try to over-ride anyone's personal choice...
By Scalextrix , 27 minutes ago
-
RE: Who’s Caved and Switched the Heating On Already?
Central heating still switched off and will be until Oc...
By AllyFish , 29 minutes ago
-
RE: Is a Valliant Inline 6kW heater a BUS buster?
I think the problem you are having comes down almost en...
By JamesPa , 57 minutes ago
-
RE: COP is not the only measure of efficiency
We keep all our TRVs fully open using the whole house a...
By Old_Scientist , 1 hour ago
-
RE: Midea ASHP – how to set weather compensation
I think it is a bug in the code, it comes on even when ...
By cathodeRay , 15 hours ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
I am pleased to say at 4pm today we have added another ...
By ASHP-BOBBA , 17 hours ago
-
RE: Buffers, hot water and cooling
@jamespa Your reasonably close! Especially with warmer ...
By dgclimatecontrol , 19 hours ago
-
RE: Renewables & Heat Pumps in the News
To unpack this a little.... 1) how many of us in this...
By Lucia , 1 day ago
-
RE: Vaillant aroTherm Plus 10kW thoughts?
@realevil the fans and fan speed / coil size (height, w...
By ASHP-BOBBA , 2 days ago
-
RE: Mitsubishi Ecodan 11kw Defrosting Issue.
@morgan this can just be done by your sepecilist when t...
By ASHP-BOBBA , 2 days ago
-
RE: Anyone still weathering it out with Agile?
@toodles I guess it all comes down to import averages. ...
By Tim441 , 2 days ago
-
RE: 300 Liter Tank - Do I have to heat it all?
The size of DHW tank affects the anti-legionella cycle....
By Transparent , 2 days ago
-
RE: Heat Pump SCOPs – The Truth Might Not Be What You Think
@scalextrix Name plate capacity
By HCas , 2 days ago
-
RE: Solar Thermal DHW and ASHP
I was originally contemplating a solar thermal installa...
By jamespetts , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
My system installed in July 2024 has produced 6.4mWh in...
By jamespetts , 2 days ago
-
RE: A Customer's Lessons Learnt from a Heat Pump Installation in a Large House
@judith thanks for your suggestions. Starting from col...
By GrahamF , 3 days ago
-
RE: Inventor (Midea) Heat Pump short cycling advice
I switched to "fan coil mode" to be able to set water t...
By immunity , 3 days ago
-
RE: DESNZ doing a survey which asks the right questions!
Without a survey their only source of data is probably ...
By JamesPa , 3 days ago