Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 7, 2026
@gary I get where you’re coming from. But I don’t think you’re undersized . You’re trying to cram in all the heat your house needs into certain peri...
Hi, I'm saying this from my experience, not as a heating expert: Your compressor is turned off for too long periods. You may think the UFH is at ...
@gary how much UFH and how much rads are you? Whats your screed depth and pipe size?
@jamespa yeah, i agree. The time required to fine tune a system is not economical. I absolutely understand why heat pump companies oversize, stat ...
@jamespa yeah, I agreed. My son’s bedroom is on the ground floor with his sisters room above. I need to keep his room all night to over 20 so the fabr...
@jamespa yep, and this is what I'm doing it's the eveness of the spec. If your going to oversize, do it evenly. BUT, and it's a big BUT, having...
@gary Its not the integral tank, so I have a separate pump. My data from the second 1/2 of the winter is that 11.2 should be OK to cover this ho...
@sunandair I can't get my system higher than 35 or 36 degrees, The only way to do that would be to start to close more of the secondary system off.
@sandman1600 What I mean is, your UFH power is 79wm2 I think, at mean water temp 50, so in your house that is 9. something kw of power. they desi...
@sandman1600 If your heat loss is really 14, and your UFH capacity at mean water temp 50 is 9kw, if they are right, the the pump won’t be your prob...
More like “the heat loss report is the heat loss report” The actual heat loss, well, you’ll have live evidence. if increasing primary flow withou...
- 27 Forums
- 2,748 Topics
- 64.7 K Posts
- 1,066 Online
- 7,155 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
Volumisers are normally plumbed so that they are in the...
By JamesPa , 5 hours ago
-
@toodles possibly. The £9k labour charge for 4-5 days w...
By AndrewJ , 9 hours ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 13 hours ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 1 day ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 1 day ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 1 day ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
There is scope for product development here. I for one...
By JamesPa , 2 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 2 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 5 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
First time poster here but I can share my experience as...
By SCH , 5 days ago
-
RE: Is it the house or the equipment?
...which, I've found out, is pretty much impossible to ...
By Majordennisbloodnok , 5 days ago