@ronin92 - these temps are not easy to measure accurately. The clip on thermometers are typically +/- 5 degrees so not discriminating enough. I use a ...
@derek-m - Thank you for the detailed explanation of the principles behind how a PHE works. That is indeed my understanding of the principles, though ...
@derek-m - yes, we did, but didn't get to the bottom of it, largely because there weren't cold enough ambients to test the system. @kev-m - I agree ...
@kev-m - that's interesting, and makes sense, and fits with what I observed about the power reading in the Midea controller, around 5kW when it was on...
@editor - useful images. Using my rather more basic IR thermometer I continue to have a roughly 5 degree difference between the top and bottom of most...
My flow temp is 34 deg now and my kitchen rad is definitely cooler on the bottom (with my uncalibrated but able to register differences quite well, ha...
@editor - these stats are always fascinating. Or perhaps I should get out more often. A couple of quotes: "Since applications for grants opened for ...
Very informative. Unfortunately I was tied to using a Midea unit, by virtue of it being baked into the planning and listed building consents. The Mide...
Indeed it is, but it is currently summer, so no need for 16kW, plus I am wary of voiding my warranty because I have tinkered with the settings, hence ...
@derek-m - thanks for posting this spreadsheet again, it is worthy of many postings! Total Heating Elements output (at delta t 50, ie fossil fuel delt...
It's a long story, spread out over many months, and covered in some detail in earlier posts in this thread. In summary, it was specified by my install...
You may well be right, but I don't think I can be sure, because two things changed, but not quite at the same time: the outside temp and the heat pump...
- 26 Forums
- 2,300 Topics
- 51.6 K Posts
- 292 Online
- 5,965 Members
Join Us!
Podcast Picks
Latest Posts
-
Unfortunately COP for DHW will always be lower because ...
By JamesPa , 12 minutes ago
-
RE: Electricity price predictions
Er not sure that is universally true. Mine is cheaper ...
By JamesPa , 20 minutes ago
-
RE: Heat Pump on Flat Roof Low Frequency Noise from Detached Neighbor
1) talk to your neighbour, that's unacceptable noise, a...
By davidnolan22 , 23 minutes ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
Firstly you are getting your units mixed up which is a ...
By JamesPa , 1 hour ago
-
RE: Buffer tank bypass on EDF Ideal heat pump installation
I would bypass the buffer tank in one of flow or return...
By JamesPa , 2 hours ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira
I agree with all of that. 220 pages is perhaps 210-215...
By JamesPa , 2 hours ago
-
RE: Why Millions of UK Homes Struggle With Heat Pumps
One of those brilliant ideas that is obvious with hinds...
By Lenny , 2 hours ago
-
RE: Don’t Install a Heat Pump Until You Read This
@davidnolan22 Perhaps you could post some more info a...
By JamesPa , 2 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
OK. I have 2.8 for DHW and 3.4 for space heating runni...
By JamesPa , 2 hours ago
-
RE: 10kw heat pump run in 24*7 data?
Some observations: 1. I for one don't know the Vailla...
By cathodeRay , 2 hours ago
-
RE: Commencing on an ASHP Installation Process
Given that this thread ultimately turned out to be a di...
By Sheriff Fatman , 12 hours ago
-
Ecodan - Flow temperature spiking causing shutdown
Hi everyone, looking for some help. I am in a new bu...
By Gl3484 , 12 hours ago
-
Solis AI is on the right track to leverage the battery:...
By Batpred , 14 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Thanks James, its honestly hard to keep it tog...
By Crimson , 16 hours ago
-
RE: Extend the colder range of the weather compensation curve?
Thanks for replies. That's good to hear and wanted to ...
By TheBinMan , 16 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: KevB Manufacturer: Ideal Model: 5kW ...
By KevB , 17 hours ago
-
RE: DHW heat loss through pumps.
Hi @ngillam I don't have anything as sophisticated for ...
By Marzipan71 , 20 hours ago
-
RE: Has anyone seen this problem before? Huge anticycling times
For the information of others. Vaillent came today, che...
By jamesh , 20 hours ago
-
RE: Here is my heat pump installation with questionable COP in Italy
Hi, and welcome to the forum. I cant quite u...
By JamesPa , 1 day ago
-
I signed up to Havenwise control on the day after the h...
By Sheriff Fatman , 1 day ago