Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

cathodeRay
cathodeRay
@cathoderay
Moderator
Famed Member
Joined: Feb 28, 2022
Last seen: Sep 7, 2026
Topics: 18 / Replies: 3006
Reply
RE: How to Solve Mould and Mildew Issues in Renovated Properties

Indeed, and it is a complex area. My primary observation (I have an old leaky grade II listed building) is that installing a heat pump appears to have...

2 years ago
Forum
Reply
RE: Midea ASHP – how to set weather compensation

@mphb - thanks, a useful link. Using google translate, I found the post contains this: "There are 8 heating curves pre-programmed, with "1" being th...

2 years ago
Reply
RE: Midea ASHP – how to set weather compensation

That is exactly what weather compensation is, and it is what you want. One zone, no TRVs (with very rare exceptions) and weather compensation. Strictl...

2 years ago
Reply
RE: Midea ASHP – how to set weather compensation

@iwolf - I have a very similar if not the same heat pump. Yours has a suffix, perhaps that means it is the German model. I don't speak German I'm afra...

2 years ago
Reply
RE: (Controversy Warning) Is it time to relax Listed Status for Insulation purposes?

My reading of the rules is that secondary glazing is definitely OK in listed building. The only alteration is a removable magnetic strip, on a par wit...

2 years ago
Forum
Reply
RE: (Controversy Warning) Is it time to relax Listed Status for Insulation purposes?

Hmm, the joys of old buildings! Are the metal frames mounted in wooden frames, as is often the case? If so, and enough exposed surface is available, t...

2 years ago
Forum
Reply
RE: (Controversy Warning) Is it time to relax Listed Status for Insulation purposes?

@toodles - perhaps more likely cool chilled out bats, the heat pump after all puts out cool air. But good to be free of bat poo. @majordennisbloodno...

2 years ago
Forum
Reply
RE: (Controversy Warning) Is it time to relax Listed Status for Insulation purposes?

@toodles - as you may recall, I have a listed (Grade II) building, and so have some experience in this area. It doesn't have to be expensive, that isn...

2 years ago
Forum
Reply
RE: Simulation of ASHP with Gas boiler as part of decision process

The design/heat loss calculations IATs varied between rooms, range 19 to 22 degrees, to satisfy MCS requirements. The average was 20.4, say 2 degrees ...

2 years ago
Reply
RE: Simulation of ASHP with Gas boiler as part of decision process

That's a good point, I forgot i am only dealing with a steady state linear relationship that doesn't involve a declining COP. Here's the linear regres...

2 years ago
Reply
RE: Simulation of ASHP with Gas boiler as part of decision process

I think you are making assumptions here. Review the data for Jan 2024 above, and posts passim that include setback periods. The house has a relatively...

2 years ago
Reply
RE: Simulation of ASHP with Gas boiler as part of decision process

I appreciate this thread may appear to be going off piste but I think if we take OP's original statement ('My approach is then, to simulate an ASHP wi...

2 years ago