@haggistrap I have no idea what the COP is mine does not tell me anywhere. The HP is effectively on most of the time. I only use Heat on Demand for ...
@hcas I use schedules both with the wall stat and TRVs.
@haggistrap Mine is ok until ambient gets down nearer freezing, say sub 4 degrees. Be interesting to hear how yours performs with a full charge of ref...
@toodles Hive is working fine for me after the mods I did. However, I agree it would have been useless without it. Hive do not actually recommend its ...
@haggistrap Those are porky pies. It will not give those outlet temps. I will look through the data sheets I have but I am petty sure they say differe...
@haggistrap Terry, our HP do not run at 70C. 55 is about the max. It will run cooler . Mine is weather dependent and runs between 35 and 50 normally f...
@oswiu have you model before, External unit is EPRA18DAV3, supposedly a 18 kW High Temp Altherma unit. If is installed as per instructions , no stru...
@batalto Thank you, I am well aware of the physics , but you have to make enough heat to warm the house adequately. My present weather compensation is...
@batalto It will not make any difference unless it stops continuous defrosting, or at least significantly extends the interval between defrosts. I can...
@batalto I know and understand what you mean. I am trying to work out what temp I should set for the current ambient, based on what it is reaching on ...
@batalto will reduce further tomorrow, just trying to work out what the mean temperature ( with the HP cycling on and off), is at the moment that is m...
@derek-m yes weather compensated. Will try lower temperatures tomorrow.
- 23 Forums
- 2,098 Topics
- 46.2 K Posts
- 279 Online
- 3,385 Members
Latest Posts
-
RE: Ecodan consuming 100kwh per day in new build!!!
@anca1808 I have just reviewed the whole thread. In s...
By JamesPa , 17 minutes ago
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 11 hours ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 11 hours ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 18 hours ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 23 hours ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 1 day ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 2 days ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 2 days ago
-
If you are thinking of heating on the immersion conside...
By JamesPa , 3 days ago
-
RE: Surface mount or bury primaries for heat pump installation?
@tomasmcguinness, I think your best bet would be using ...
By Aventus Eco , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles all depends on asking the right questions! And...
By Tim441 , 3 days ago
-
RE: Commencing on an ASHP Installation Process
I received confirmation this morning that my Greener Ho...
By Sheriff Fatman , 4 days ago
-
@jamespa Thanks for the advice - very helpful. I had al...
By abam48 , 5 days ago